CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Cardiac Troponin Elevation in Patients Without a Specific Diagnosis 2019 AHA/ACC/HRS Focused Update of the 2014 AHA/ACC/HRS Guideline for the Management of Patients With Atrial Fibrillation: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines and the Heart Rhythm Society Thin Composite-Wire-Strut Zotarolimus-Eluting Stents Versus Ultrathin-Strut Sirolimus-Eluting Stents in BIONYX at 2 Years Acute Myocardial Injury in Patients Hospitalized With COVID-19 Infection: A Review Two-Year Outcomes and Predictors of Target Lesion Revascularization for Non-Left Main Coronary Bifurcation Lesions Following Two-Stent Strategy With 2nd-Generation Drug-Eluting Stents Predicting Major Adverse Events in Patients With Acute Myocardial Infarction A Randomized Trial Comparing the NeoVas Sirolimus-Eluting Bioresorbable Scaffold and Metallic Everolimus-Eluting Stents Outcome of Applying the ESC 0/1-hour Algorithm in Patients With Suspected Myocardial Infarction COVID-19 and Thrombotic or Thromboembolic Disease: Implications for Prevention, Antithrombotic Therapy, and Follow-up Heart Disease and Stroke Statistics-2019 Update: A Report From the American Heart Association

Original Research2013 Sep 1;112(5):642-6.

JOURNAL:Am J Cardiol. Article Link

Usefulness of intravascular ultrasound to predict outcomes in short-length lesions treated with drug-eluting stents

Yoon YW, Shin S, RESET Investigators et al. Keywords: IVUS guided PCI; angiography-guided PCI; DES; outcome

ABSTRACT


Intravascular ultrasound (IVUS) offers tomographic images of the coronary artery, helping physicians to refine drug-eluting stent (DES) implantation in angiographically complex lesions. However, controversy exists regarding whether the routine use of IVUS in short-length lesions leads to improved clinical outcomes after DES implantation. Therefore, we evaluated the usefulness of IVUS in predicting major adverse cardiac events (MACE), including cardiovascular death, myocardial infarction, or target vessel revascularization, at 1 year after DES implantation in short-length lesions. The present study was a subanalysis of the REal Safety and Efficacy of a 3-month dual antiplatelet Therapy following Endeavor zotarolimus-eluting stent implantation (RESET) study with different clinical outcome parameters. The study population consisted of 662 patients with IVUS guidance and 912 patients with angiography guidance who underwent DES implantation (stent length ≤24 mm). In the IVUS-guided group, adjuvant postdilation was more frequently performed (43.0% vs 34.6%, p <0.001), and the postintervention minimal lumen diameters were greater (2.88 ± 0.44 mm vs 2.72 ± 0.43 mm, p <0.001). MACE occurred in 15 IVUS-guided (2.3%) and 19 angiographically guided (2.1%) patients (p = 0.872). In a subset of patients with diabetes mellitus (n = 292), the MACE rate was 3.4% (n = 4) and 1.7% (n = 3) in the IVUS- and angiographically guided patients, respectively (p = 0.384). The MACE rate in the IVUS- and angiographically guided patients with acute coronary syndrome (n = 601) was 1.1% (n = 3) and 2.7% (n = 9), respectively (p = 0.194). The clinical benefits of IVUS-guided DES implantation compared with angiographically guided DES implantation in short-length lesions could not be confirmed even in patients with clinically high-risk presentations (acute coronary syndrome and diabetes mellitus). In conclusion, routine IVUS guidance does not provide clinical benefits when performing short-length DES implantation.