Two-Year Outcomes with a Magnetically Levitated Cardiac Pump in Heart Failure Intravascular Ultrasound to Guide Left Main Stem Intervention: A Sub-Study of the NOBLE Trial Atrial Fibrillation and the Prognostic Performance of Biomarkers in Heart Failure The year in cardiovascular medicine 2020: heart failure and cardiomyopathies Feasibility of Coronary Access and Aortic Valve Reintervention in Low-Risk TAVR Patients Nitrosative stress drives heart failure with preserved ejection fraction Impact of plaque components on no-reflow phenomenon after stent deployment in patients with acute coronary syndrome: a virtual histology-intravascular ultrasound analysis Clinical trial design and rationale of the Multicenter Study of MagLev Technology in Patients Undergoing Mechanical Circulatory Support Therapy With HeartMate 3 (MOMENTUM 3) investigational device exemption clinical study protocol Unexpectedly Low Natriuretic Peptide Levels in Patients With Heart Failure The Utility of Contrast Medium Fractional Flow Reserve in Functional Assessment Of Coronary Disease in Daily Practice

Original Research2014 Aug;174(8):1360-6.

JOURNAL:JAMA Intern Med. Article Link

Long-term survival in patients undergoing percutaneous interventions with or without intracoronary pressure wire guidance or intracoronary ultrasonographic imaging: a large cohort study

Fröhlich GM, Redwood S, Rakhit R et al. Keywords: IVUS guided PCI; FFR; DES; outcome; cohort

ABSTRACT



IMPORTANCE - Intracoronary pressure wire-derived measurements of fractional flow reserve (FFR) and intravascular ultrasonography (IVUS) provide functional and anatomical information that can be used to guide coronary stent implantation. Although these devices are widely used and recommended by guidelines, limited data exist about their effect on clinical end points.


OBJECTIVE - To determine the effect on long-term survival of using FFR and IVUS during percutaneous coronary intervention (PCI).


DESIGN AND SETTING - Cohort study based on the pan-London (United Kingdom) PCI registry. In total, 64,232 patients are included in this registry covering the London, England, area.


PARTICIPANTS - All patients (n = 41,688) who underwent elective or urgent PCI in National Health Service hospitals in London between January 1, 2004, and July 31, 2011, were included. Patients with ST-segment elevation myocardial infarction (n = 11,370) were excluded.


INTERVENTIONS - Patients underwent PCI guided by angiography (visual lesion assessment) alone, PCI guided by FFR, or IVUS-guided PCI.


MAIN OUTCOMES AND MEASURES - The primary end point was all-cause mortality at a median of 3.3 years.


RESULTS - Fractional flow reserve was used in 2767 patients (6.6%) and IVUS was used in 1831 patients (4.4%). No difference in mortality was observed between patients who underwent angiography-guided PCI compared with patients who underwent FFR-guided PCI (hazard ratio, 0.88; 95% CI, 0.67-1.16; P = .37). Patients who underwent IVUS had a slightly higher adjusted mortality (hazard ratio, 1.39; 95% CI, 1.09-1.78; P = .009) compared with patients who underwent angiography-guided PCI. However, this difference was no longer statistically significant in a propensity score-based analysis (hazard ratio, 1.33; 95% CI, 0.85-2.09; P = .25). The mean (SD) number of implanted stents was lower in the FFR group (1.1 [1.2] stents) compared with the IVUS group (1.6 [1.3]) and the angiography-guided group (1.7 [1.1]) (P < .001).


CONCLUSIONS AND RELEVANCE - In this large observational study, FFR-guided PCI and IVUS-guided PCI were not associated with improved long-term survival compared with standard angiography-guided PCI. The use of FFR was associated with the implantation of fewer stents.