CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Cardiac Resynchronization Therapy in Inotrope-Dependent Heart Failure Patients - A Systematic Review and Meta-Analysis Meta-analysis of outcomes after intravascular ultrasound-guided versus angiography-guided drug-eluting stent implantation in 26,503 patients enrolled in three randomized trials and 14 observational studies Fluid Volume Overload and Congestion in Heart Failure: Time to Reconsider Pathophysiology and How Volume Is Assessed Mechanical complications of everolimus-eluting stents associated with adverse events: an intravascular ultrasound study Optical frequency-domain imaging findings to predict good stent expansion after rotational atherectomy for severely calcified coronary lesions Circulating sST2 and catestatin levels in patients with acute worsening of heart failure: a report from the CATSTAT-HF study Impact of intravascular ultrasound-guided percutaneous coronary intervention on long-term clinical outcomes in a real world population Plaque composition by intravascular ultrasound and distal embolization after percutaneous coronary intervention Association of Smoking Status With Long‐Term Mortality and Health Status After Transcatheter Aortic Valve Replacement: Insights From the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry Role of Proximal Optimization Technique Guided by Intravascular Ultrasound on Stent Expansion, Stent Symmetry Index, and Side-Branch Hemodynamics in Patients With Coronary Bifurcation Lesions

Original Research2014 Aug;174(8):1360-6.

JOURNAL:JAMA Intern Med. Article Link

Long-term survival in patients undergoing percutaneous interventions with or without intracoronary pressure wire guidance or intracoronary ultrasonographic imaging: a large cohort study

Fröhlich GM, Redwood S, Rakhit R et al. Keywords: IVUS guided PCI; FFR; DES; outcome; cohort

ABSTRACT



IMPORTANCE - Intracoronary pressure wire-derived measurements of fractional flow reserve (FFR) and intravascular ultrasonography (IVUS) provide functional and anatomical information that can be used to guide coronary stent implantation. Although these devices are widely used and recommended by guidelines, limited data exist about their effect on clinical end points.


OBJECTIVE - To determine the effect on long-term survival of using FFR and IVUS during percutaneous coronary intervention (PCI).


DESIGN AND SETTING - Cohort study based on the pan-London (United Kingdom) PCI registry. In total, 64,232 patients are included in this registry covering the London, England, area.


PARTICIPANTS - All patients (n = 41,688) who underwent elective or urgent PCI in National Health Service hospitals in London between January 1, 2004, and July 31, 2011, were included. Patients with ST-segment elevation myocardial infarction (n = 11,370) were excluded.


INTERVENTIONS - Patients underwent PCI guided by angiography (visual lesion assessment) alone, PCI guided by FFR, or IVUS-guided PCI.


MAIN OUTCOMES AND MEASURES - The primary end point was all-cause mortality at a median of 3.3 years.


RESULTS - Fractional flow reserve was used in 2767 patients (6.6%) and IVUS was used in 1831 patients (4.4%). No difference in mortality was observed between patients who underwent angiography-guided PCI compared with patients who underwent FFR-guided PCI (hazard ratio, 0.88; 95% CI, 0.67-1.16; P = .37). Patients who underwent IVUS had a slightly higher adjusted mortality (hazard ratio, 1.39; 95% CI, 1.09-1.78; P = .009) compared with patients who underwent angiography-guided PCI. However, this difference was no longer statistically significant in a propensity score-based analysis (hazard ratio, 1.33; 95% CI, 0.85-2.09; P = .25). The mean (SD) number of implanted stents was lower in the FFR group (1.1 [1.2] stents) compared with the IVUS group (1.6 [1.3]) and the angiography-guided group (1.7 [1.1]) (P < .001).


CONCLUSIONS AND RELEVANCE - In this large observational study, FFR-guided PCI and IVUS-guided PCI were not associated with improved long-term survival compared with standard angiography-guided PCI. The use of FFR was associated with the implantation of fewer stents.