CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Diagnostic performance of noninvasive myocardial perfusion imaging using single-photon emission computed tomography, cardiac magnetic resonance, and positron emission tomography imaging for the detection of obstructive coronary artery disease: a meta-analysis Transcatheter aortic-valve replacement with a self-expanding prosthesis Lipid-Modifying Agents, From Statins to PCSK9 Inhibitors: JACC Focus Seminar Lateral Wall Dysfunction Signals Onset of Progressive Heart Failure in Left Bundle Branch Block Simple Electrocardiographic Measures Improve Sudden Arrhythmic Death Prediction in Coronary Disease Randomized comparison of clinical outcomes between intravascular ultrasound and angiography-guided drug-eluting stent implantation for long coronary artery stenoses Contemporary real-world outcomes of surgical aortic valve replacement in 141,905 low-risk, intermediate-risk, and high-risk patients Incidence, predictors, and outcomes associated with acute kidney injury in patients undergoing transcatheter aortic valve replacement: from the BRAVO-3 randomized trial Circadian-Regulated Cell Death in Cardiovascular Diseases Clinical impact of PCSK9 inhibitor on stabilization and regression of lipid-rich coronary plaques: a near-infrared spectroscopy study

Original Research2014 Aug;174(8):1360-6.

JOURNAL:JAMA Intern Med. Article Link

Long-term survival in patients undergoing percutaneous interventions with or without intracoronary pressure wire guidance or intracoronary ultrasonographic imaging: a large cohort study

Fröhlich GM, Redwood S, Rakhit R et al. Keywords: IVUS guided PCI; FFR; DES; outcome; cohort

ABSTRACT



IMPORTANCE - Intracoronary pressure wire-derived measurements of fractional flow reserve (FFR) and intravascular ultrasonography (IVUS) provide functional and anatomical information that can be used to guide coronary stent implantation. Although these devices are widely used and recommended by guidelines, limited data exist about their effect on clinical end points.


OBJECTIVE - To determine the effect on long-term survival of using FFR and IVUS during percutaneous coronary intervention (PCI).


DESIGN AND SETTING - Cohort study based on the pan-London (United Kingdom) PCI registry. In total, 64,232 patients are included in this registry covering the London, England, area.


PARTICIPANTS - All patients (n = 41,688) who underwent elective or urgent PCI in National Health Service hospitals in London between January 1, 2004, and July 31, 2011, were included. Patients with ST-segment elevation myocardial infarction (n = 11,370) were excluded.


INTERVENTIONS - Patients underwent PCI guided by angiography (visual lesion assessment) alone, PCI guided by FFR, or IVUS-guided PCI.


MAIN OUTCOMES AND MEASURES - The primary end point was all-cause mortality at a median of 3.3 years.


RESULTS - Fractional flow reserve was used in 2767 patients (6.6%) and IVUS was used in 1831 patients (4.4%). No difference in mortality was observed between patients who underwent angiography-guided PCI compared with patients who underwent FFR-guided PCI (hazard ratio, 0.88; 95% CI, 0.67-1.16; P = .37). Patients who underwent IVUS had a slightly higher adjusted mortality (hazard ratio, 1.39; 95% CI, 1.09-1.78; P = .009) compared with patients who underwent angiography-guided PCI. However, this difference was no longer statistically significant in a propensity score-based analysis (hazard ratio, 1.33; 95% CI, 0.85-2.09; P = .25). The mean (SD) number of implanted stents was lower in the FFR group (1.1 [1.2] stents) compared with the IVUS group (1.6 [1.3]) and the angiography-guided group (1.7 [1.1]) (P < .001).


CONCLUSIONS AND RELEVANCE - In this large observational study, FFR-guided PCI and IVUS-guided PCI were not associated with improved long-term survival compared with standard angiography-guided PCI. The use of FFR was associated with the implantation of fewer stents.