Prognostic value of coronary artery calcium screening in subjects with and without diabetes Transcatheter Aortic Valve Replacement vs Surgical Replacement in Patients With Pure Aortic Insufficiency The Role of the Pericardium in Heart Failure: Implications for Pathophysiology and Treatment Three vs twelve months of dual antiplatelet therapy after zotarolimus-eluting stents: the OPTIMIZE randomized trial The conductive function of biopolymer corrects myocardial scar conduction blockage and resynchronizes contraction to prevent heart failure Incidence, predictors, and outcomes associated with acute kidney injury in patients undergoing transcatheter aortic valve replacement: from the BRAVO-3 randomized trial Long-term effects of intensive glucose lowering on cardiovascular outcomes Percutaneous Left Atrial Appendage Closure for Stroke Prophylaxis in Patients With Atrial Fibrillation: 2.3-Year Follow-up of the PROTECT AF (Watchman Left Atrial Appendage System for Embolic Protection in Patients With Atrial Fibrillation) Trial Coronary plaque redistribution after stent implantation is determined by lipid composition: A NIRS-IVUS analysis ACC/AHA Versus ESC Guidelines on Dual Antiplatelet Therapy JACC Guideline Comparison: JACC State-of-the-Art Review

Original Research2015 Aug;19(16):3012-7.

JOURNAL:Eur Rev Med Pharmacol Sci. Article Link

The impact of intravascular ultrasound guidance during drug eluting stent implantation on angiographic outcomes

Yazici HU, Agamaliyev M, Aydar Y et al. Keywords: IVUS guided PCI; DES; outcome; minimal luminal diameter; net acute gain

ABSTRACT


OBJECTIVE - Major limitation for the use of stent in the treatment of coronary artery disease is development of stent restenosis. The impact of intravascular ultrasound (IVUS) guidance during drug eluting stent (DES) implantation is presently not yet well established.


PATIENTS AND METHODS - For the present study, we included 30 patients who received DES with IVUS-guided stenting (Group A) and 30 patients receiving the DES without IVUS-guided stenting (Group B). The patients were evaluated for their ninth month control angiographies and were followed during two years for the development of relevant clinical events after the DES implantations. The angiographic and clinical results were compared between the groups.


RESULTS - After the percutaneous intervention, the minimal luminal diameter and net acute gain were significantly increased in Group A in respect to Group B (3.3 ± 0.34 vs. 2.8 ± 0.33, p < 0.01). Moreover, the rate for performing post-dilatation following stent implantation was higher in Group A than in Group B (p = 0.01). By contrast, stent restenosis rates were similar between the groups (p > 0.3).


CONCLUSIONS - The present results indicate that the use of IVUS for the implantation of DES can increase the success rate of the intervention. The IVUS guidance during DES implantation can be complementary percutaneous intervention, in particularly by detecting the situations that need for post-dilatation.