CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Wearable Cardioverter-Defibrillator Therapy for the Prevention of Sudden Cardiac Death A Systematic Review and Meta-Analysis A Randomized Trial of a 1-Hour Troponin T Protocol in Suspected Acute Coronary Syndromes: The Rapid Assessment of Possible ACS In the Emergency Department with High Sensitivity Troponin T (RAPID-TnT) Study Transcatheter Aortic-Valve Replacement with a Self-Expanding Valve in Low-Risk Patients Fourth Universal Definition of Myocardial Infarction (2018) Contemporary Management of Cardiogenic Shock: A Scientific Statement From the American Heart Association Current Interventions for the Left Main Bifurcation Investigating methotrexate toxicity within a randomized double-blinded, placebo-controlled trial: Rationale and design of the Cardiovascular Inflammation Reduction Trial-Adverse Events (CIRT-AE) Study One or two stents for the distal Left Main bifurcation The DK crush V study - The DK crush V study 2017 ESC Guidelines for the management of acute myocardial infarction in patients presenting with ST-segment elevation: The Task Force for the management of acute myocardial infarction in patients presenting with ST-segment elevation of the European Society of Cardiology (ESC) Progression of Device-Detected Subclinical Atrial Fibrillation and the Risk of Heart Failure

Original Research2015 Aug;19(16):3012-7.

JOURNAL:Eur Rev Med Pharmacol Sci. Article Link

The impact of intravascular ultrasound guidance during drug eluting stent implantation on angiographic outcomes

Yazici HU, Agamaliyev M, Aydar Y et al. Keywords: IVUS guided PCI; DES; outcome; minimal luminal diameter; net acute gain

ABSTRACT


OBJECTIVE - Major limitation for the use of stent in the treatment of coronary artery disease is development of stent restenosis. The impact of intravascular ultrasound (IVUS) guidance during drug eluting stent (DES) implantation is presently not yet well established.


PATIENTS AND METHODS - For the present study, we included 30 patients who received DES with IVUS-guided stenting (Group A) and 30 patients receiving the DES without IVUS-guided stenting (Group B). The patients were evaluated for their ninth month control angiographies and were followed during two years for the development of relevant clinical events after the DES implantations. The angiographic and clinical results were compared between the groups.


RESULTS - After the percutaneous intervention, the minimal luminal diameter and net acute gain were significantly increased in Group A in respect to Group B (3.3 ± 0.34 vs. 2.8 ± 0.33, p < 0.01). Moreover, the rate for performing post-dilatation following stent implantation was higher in Group A than in Group B (p = 0.01). By contrast, stent restenosis rates were similar between the groups (p > 0.3).


CONCLUSIONS - The present results indicate that the use of IVUS for the implantation of DES can increase the success rate of the intervention. The IVUS guidance during DES implantation can be complementary percutaneous intervention, in particularly by detecting the situations that need for post-dilatation.