CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Invasive Coronary Physiology After Stent Implantation: Another Step Toward Precision Medicine Dynamic Myocardial Ultrasound Localization Angiography Macrophage MST1/2 Disruption Impairs Post-Infarction Cardiac Repair via LTB4 Biolimus-A9 polymer-free coated stent in high bleeding risk patients with acute coronary syndrome: a Leaders Free ACS sub-study Percutaneous coronary intervention using a combination of robotics and telecommunications by an operator in a separate physical location from the patient: an early exploration into the feasibility of telestenting (the REMOTE-PCI study) Frequency, Regional Variation, and Predictors of Undetermined Cause of Death in Cardiometabolic Clinical Trials: A Pooled Analysis of 9259 Deaths in 9 Trials A Randomized Trial to Assess Regional Left Ventricular Function After Stent Implantation in Chronic Total Occlusion The REVASC Trial Double kissing crush in left main coronary bifurcation lesions: A crushing blow to the rival stenting techniques Digital learning and the future cardiologist Percutaneous Support Devices for Percutaneous Coronary Intervention

Original Research2015 Aug;19(16):3012-7.

JOURNAL:Eur Rev Med Pharmacol Sci. Article Link

The impact of intravascular ultrasound guidance during drug eluting stent implantation on angiographic outcomes

Yazici HU, Agamaliyev M, Aydar Y et al. Keywords: IVUS guided PCI; DES; outcome; minimal luminal diameter; net acute gain

ABSTRACT


OBJECTIVE - Major limitation for the use of stent in the treatment of coronary artery disease is development of stent restenosis. The impact of intravascular ultrasound (IVUS) guidance during drug eluting stent (DES) implantation is presently not yet well established.


PATIENTS AND METHODS - For the present study, we included 30 patients who received DES with IVUS-guided stenting (Group A) and 30 patients receiving the DES without IVUS-guided stenting (Group B). The patients were evaluated for their ninth month control angiographies and were followed during two years for the development of relevant clinical events after the DES implantations. The angiographic and clinical results were compared between the groups.


RESULTS - After the percutaneous intervention, the minimal luminal diameter and net acute gain were significantly increased in Group A in respect to Group B (3.3 ± 0.34 vs. 2.8 ± 0.33, p < 0.01). Moreover, the rate for performing post-dilatation following stent implantation was higher in Group A than in Group B (p = 0.01). By contrast, stent restenosis rates were similar between the groups (p > 0.3).


CONCLUSIONS - The present results indicate that the use of IVUS for the implantation of DES can increase the success rate of the intervention. The IVUS guidance during DES implantation can be complementary percutaneous intervention, in particularly by detecting the situations that need for post-dilatation.