CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Clinical impact of PCSK9 inhibitor on stabilization and regression of lipid-rich coronary plaques: a near-infrared spectroscopy study Considerations for Optimal Device Selection in Transcatheter Aortic Valve Replacement: A Review Primary Prevention Trial Designs Using Coronary Imaging: A National Heart, Lung, and Blood Institute Workshop Impact of post-intervention minimal stent area on 9-month follow-up patency of paclitaxel-eluting stents: an integrated intravascular ultrasound analysis from the TAXUS IV, V, and VI and TAXUS ATLAS Workhorse, Long Lesion, and Direct Stent Trials Clinical impact of conduction disturbances in transcatheter aortic valve replacement recipients: a systematic review and meta-analysis Association of Reduced Apical Untwisting With Incident HF in Asymptomatic Patients With HF Risk Factors Percutaneous Coronary Intervention for Vulnerable Coronary Atherosclerotic Plaque Why and How to Measure Aortic Valve Calcification in Patients With Aortic Stenosis Intracoronary stenting without anticoagulation accomplished with intravascular ultrasound guidance Contribution of stent underexpansion to recurrence after sirolimus-eluting stent implantation for in-stent restenosis

Original Research2018 Oct 8. [Epub ahead of print]

JOURNAL:Catheter Cardiovasc Interv. Article Link

Self-expandable sirolimus-eluting stents compared to second-generation drug-eluting stents for the treatment of the left main: A propensity score analysis from the SPARTA and the FAILS-2 registries

Montefusco A, D'Ascenzo F, Gili S et al. Keywords: percutaneous coronary intervention; second-generation drug-eluting stent; self-expandable stent; unprotected left main

ABSTRACT


OBJECTIVES - To compare the effectiveness and safety of self-expandable, sirolimus-eluting Stentys stents (SES) and second-generation drug-eluting stents (DES-II) for the treatment of the unprotected left main (ULM).


BACKGROUND - SES may provide a valuable option to treat distal ULM, particularly when significant caliber gaps with side branches are observed.


METHODS - Patients from the multicenter SPARTA (clinicaltrials.gov -  NCT02784405) and FAILS2 registries were included. Propensity-score with matching was performed to account for the lack of randomization. Primary end-point was the rate of major adverse cardiovascular events (MACE, a composite of all cause death, myocardial infarction, target lesion revascularization [TLR], unstable angina and definite stent thrombosis [ST]). Single components of MACE were the secondary end-points.


RESULTS - Overall, 151 patients treated with SES and 1270 with DES-II were included; no differences in MACE rate at 250 days were observed (9.8% vs. 11.5%, P = 0.54). After propensity score with matching, 129 patients treated with SES and 258 with DES-II, of which about a third of female gender, were compared. After a follow-up of 250 days, MACE rate did not differ between the two groups (9.9% vs. 8.5%, P = 0.66), as well as the rate of ULM TLR (1.6% vs. 3.1%, P = 0.36) and definite ST (0.8% vs. 1.2%, P = 0.78). These results were consistent also when controlling for the treatment with provisional vs. 2-stents strategies for the ULM bifurcation.


CONCLUSION - SES use for ULM treatment was associated with a similar MACE rate compared to DES-II at an intermediate-term follow-up. SES might represent a potential option in this setting.

 

© 2018 Wiley Periodicals, Inc.