CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Intraluminal Intensity of Blood Speckle on Intravascular Ultrasound, a Novel Predictor of Periprocedural Myocardial Injury After Coronary Stenting Characterization of the Average Daily Ischemic and Bleeding Risk After Primary PCI for STEMI PCI Strategies in Patients with Acute Myocardial Infarction and Cardiogenic Shock Nonculprit Stenosis Evaluation Using Instantaneous Wave-Free Ratio in Patients With ST-Segment Elevation Myocardial Infarction Transcatheter Aortic-Valve Replacement with a Balloon-Expandable Valve in Low-Risk Patients Ranolazine in High-Risk Patients With Implanted Cardioverter-Defibrillators - The RAID Trial Comparison of Outcomes of Patients With ST-Segment Elevation Myocardial Infarction Treated by Primary Percutaneous Coronary Intervention Analyzed by Age Groups (<75, 75 to 85, and >85 Years); (Results from the Bremen STEMI Registry) Location of the culprit coronary lesion and its association with delay in door-to-balloon time (from a multicenter registry of primary percutaneous coronary intervention) Fine particulate air pollution and hospital admissions and readmissions for acute myocardial infarction in 26 Chinese cities Door to Balloon Time: Is There a Point That Is Too Short?

Clinical Trial2008 Oct;156(4):641-648.e1.

JOURNAL:Am Heart J. Article Link

A randomized controlled trial to evaluate the safety and efficacy of cardiac contractility modulation in patients with systolic heart failure: rationale, design, and baseline patient characteristics.

Abraham WT, , FIX-HF-5 Investigators and Coordinators. Keywords: QRS duration; exercise tolerance; heart failure; peak Vo(2); quality of life

ABSTRACT


Cardiac contractility modulation (CCM) signals are nonexcitatory electrical signals delivered during the cardiac absolute refractory period that enhance the strength of cardiac muscular contraction. Prior research in experimental and human heart failure has shown that CCM signals normalize phosphorylation of key proteins and expression of genes coding for proteins involved in regulation of calcium cycling and contraction. The results of prior clinical studies of CCM have supported its safety and efficacy. A large-scale clinical study, the FIX-HF-5 study, is currently underway to test the safety and efficacy of this treatment. In this article, we provide an overview of the system used to deliver CCM signals, the implant procedure, and the details and rationale of the FIX-HF-5 study design. Baseline characteristics for patients randomized in this trial are also presented.