Difference in basic concept of coronary bifurcation intervention between Korea and Japan. Insight from questionnaire in experts of Korean and Japanese bifurcation clubs Patient and Hospital Characteristics of Mitral Valve Surgery in the United States Prognostic implications of ischemia with nonobstructive coronary arteries (INOCA): Understanding risks for improving treatment Consensus standards for acquisition, measurement, and reporting of intravascular optical coherence tomography studies: a report from the International Working Group for Intravascular Optical Coherence Tomography Standardization and Validation Gut microbiota induces high platelet response in patients with ST segment elevation myocardial infarction after ticagrelor treatment Prognostic Implication of Thermodilution Coronary Flow Reserve in Patients Undergoing Fractional Flow Reserve Measurement Fractional Flow Reserve-Guided Multivessel Angioplasty in Myocardial Infarction Bench testing and coronary artery bifurcations: a consensus document from the European Bifurcation Club Left main coronary artery disease: importance, diagnosis, assessment, and management OCT compared with IVUS in a coronary lesion assessment: the OPUS-CLASS study

Clinical Trial2008 Oct;156(4):641-648.e1.

JOURNAL:Am Heart J. Article Link

A randomized controlled trial to evaluate the safety and efficacy of cardiac contractility modulation in patients with systolic heart failure: rationale, design, and baseline patient characteristics.

Abraham WT, , FIX-HF-5 Investigators and Coordinators. Keywords: QRS duration; exercise tolerance; heart failure; peak Vo(2); quality of life

ABSTRACT


Cardiac contractility modulation (CCM) signals are nonexcitatory electrical signals delivered during the cardiac absolute refractory period that enhance the strength of cardiac muscular contraction. Prior research in experimental and human heart failure has shown that CCM signals normalize phosphorylation of key proteins and expression of genes coding for proteins involved in regulation of calcium cycling and contraction. The results of prior clinical studies of CCM have supported its safety and efficacy. A large-scale clinical study, the FIX-HF-5 study, is currently underway to test the safety and efficacy of this treatment. In this article, we provide an overview of the system used to deliver CCM signals, the implant procedure, and the details and rationale of the FIX-HF-5 study design. Baseline characteristics for patients randomized in this trial are also presented.