CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Endoplasmic reticulum stress in doxorubicin-induced cardiotoxicity may be therapeutically targeted by natural and chemical compounds: A review Ablation Versus Drug Therapy for Atrial Fibrillation in Heart Failure Results From the CABANA Trial Long-Term Outcomes of Patients With Mediastinal Radiation–Associated Coronary Artery Disease Undergoing Coronary Revascularization With Percutaneous Coronary Intervention and Coronary Artery Bypass Grafting The Art of SAPIEN 3 Transcatheter Mitral Valve Replacement in Valve-in-Ring and Valve-in-Mitral-Annular-Calcification Procedures Evolving insights into the role of local shear stress in late stent failure from neoatherosclerosis formation and plaque destabilization 2020 ACC Expert Consensus Decision Pathway on Management of Bleeding in Patients on Oral Anticoagulants: A Report of the American College of Cardiology Solution Set Oversight Committee Does pulsed field ablation regress over time? A quantitative temporal analysis of pulmonary vein isolation Thirty-Day Outcomes Following Transfemoral Transseptal Transcatheter Mitral Valve Replacement: Intrepid TMVR Early Feasibility Study Results Functional Mitral Regurgitation Outcome and Grading in Heart Failure With Reduced Ejection Fraction 2015 ACC/HRS/SCAI Left Atrial Appendage Occlusion Device Societal Overview

Clinical Trial2008 Oct;156(4):641-648.e1.

JOURNAL:Am Heart J. Article Link

A randomized controlled trial to evaluate the safety and efficacy of cardiac contractility modulation in patients with systolic heart failure: rationale, design, and baseline patient characteristics.

Abraham WT, , FIX-HF-5 Investigators and Coordinators. Keywords: QRS duration; exercise tolerance; heart failure; peak Vo(2); quality of life

ABSTRACT


Cardiac contractility modulation (CCM) signals are nonexcitatory electrical signals delivered during the cardiac absolute refractory period that enhance the strength of cardiac muscular contraction. Prior research in experimental and human heart failure has shown that CCM signals normalize phosphorylation of key proteins and expression of genes coding for proteins involved in regulation of calcium cycling and contraction. The results of prior clinical studies of CCM have supported its safety and efficacy. A large-scale clinical study, the FIX-HF-5 study, is currently underway to test the safety and efficacy of this treatment. In this article, we provide an overview of the system used to deliver CCM signals, the implant procedure, and the details and rationale of the FIX-HF-5 study design. Baseline characteristics for patients randomized in this trial are also presented.