CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Transcatheter Aortic Valve Implantation Represents an Anti-Inflammatory Therapy Via Reduction of Shear Stress–Induced, Piezo-1–Mediated Monocyte Activation Coronary Microcirculation in Ischemic Heart Disease Drug-eluting stent implantation in patients with acute coronary syndrome - the Activity of Platelets after Inhibition and Cardiovascular Events: Optical Coherence Tomography (APICE OCT) study Safety of intermediate left main stenosis revascularization deferral based on fractional flow reserve and intravascular ultrasound: A systematic review and meta-regression including 908 deferred left main stenosis from 12 studies Transcatheter Versus Surgical Aortic Valve Replacement in Patients With Rheumatic Aortic Stenosis Percutaneous coronary intervention in left main coronary artery disease: the 13th consensus document from the European Bifurcation Club A randomized clinical study comparing double kissing crush with provisional stenting for treatment of coronary bifurcation lesions: results from the DKCRUSH-II (Double Kissing Crush versus Provisional Stenting Technique for Treatment of Coronary Bifurcation Lesions) trial Left atrial appendage occlusion in atrial fibrillation patients with previous intracranial bleeding: A national multicenter study Cellular origin and developmental program of coronary angiogenesis Evaluation and Management of Aortic Stenosis in Chronic Kidney Disease: A Scientific Statement From the American Heart Association

Clinical TrialVolume 11, Issue 23, December 2018

JOURNAL:JACC Cardiovasc Interv. Article Link

Comparison of 2 Different Drug-Coated Balloons in In-Stent Restenosis: The RESTORE ISR China Randomized Trial

YD Chen, L Gao, Q Qin et al. Keywords: drug-coated balloon; drug-eluting stent(s); in-segment late loss; in-stent restenosis

ABSTRACT


OBJECTIVES - The aim of the present study was to evaluate the angiographic efficacy, clinical safety, and effectiveness of the Restore paclitaxel-coated balloon in a randomized trial designed to enable the approval of the new device in China.

 

BACKGROUND - Drug-coated balloon (DCB) angioplasty offers an effective treatment for in-stent restenosis. Restore is a new DCB with a SAFEPAX shellac-ammonium salt excipient that can avoid drug washing off during catheter delivery to the target lesion site.

 

METHODS -  In the noninferiority RESTORE ISR China (Compare the Efficacy and Safety of RESTORE DEB and SeQuent Please in Chinese Patient With Coronary In-stent Restenosis) trial, eligible patients with first occurrence of drug-eluting stent ISR were randomized to the Restore DCB or SeQuent Please DCB in a 1:1 ratio stratified by diabetes. Angiographic and clinical follow-up was planned at 9 months and 1 year, respectively, in all patients. The study was powered for the primary endpoint of 9-month in-segment late loss.

 

RESULTS - Between May 2016 and July 2017, a total of 240 subjects at 12 sites were randomized to either the Restore group (n = 120) or the SeQuent Please group (n = 120). Nine-month in-segment late loss was 0.38 ± 0.50 mm with Restore versus 0.35 ± 0.47 mm with SeQuent Please; the 1-sided 97.5% upper confidence limit of the difference was 0.17 mm, achieving noninferiority of Restore compared with SeQuent Please (p for noninferiority = 0.02). Both DCBs had similar 1-year rates of target lesion failure (13.3% vs. 12.6%; p = 0.87).

 

CONCLUSIONS - In this head-to-head randomized trial, the Restore DCB was noninferior to the SeQuent Please DCB for the primary endpoint of 9-month in-segment late loss. (Compare the Efficacy and Safety of RESTORE DEB and SeQuent Please in Chinese Patient With Coronary In-stent Restenosis; NCT02944890)