CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Combining IVUS and Optical Coherence Tomography for More Accurate Coronary Cap Thickness Quantification and Stress/Strain Calculations: A Patient-Specific Three-Dimensional Fluid-Structure Interaction Modeling Approach The HACD4 haplotype as a risk factor for atherosclerosis in males Changes in One-Year Mortality in Elderly Patients Admitted with Acute Myocardial Infarction in Relation with Early Management The Impact of Proximal Vessel Tortuosity on the Outcomes of Chronic Total Occlusion Percutaneous Coronary Intervention: Insights From a Contemporary Multicenter Registry 2021 AHA/ACC/ASE/CHEST/SAEM/SCCT/SCMR Guideline for the Evaluation and Diagnosis of Chest Pain: A Report of the American College of Cardiology/American Heart Association Joint Committee on Clinical Practice Guidelines Long-term Survival following Multivessel Revascularization in Patients with Diabetes (FREEDOM Follow-On Study) Eruptive Calcified Nodules as a Potential Mechanism of Acute Coronary Thrombosis and Sudden Death Comparison of Stent Expansion Guided by Optical Coherence Tomography Versus Intravascular Ultrasound: The ILUMIEN II Study (Observational Study of Optical Coherence Tomography [OCT] in Patients Undergoing Fractional Flow Reserve [FFR] and Percutaneous Coronary Intervention) Left Ventricular Assist Device as a Bridge to Recovery for Patients With Advanced Heart Failure Stent fracture is associated with a higher mortality in patients with type-2 diabetes treated by implantation of a second-generation drug-eluting stent

Clinical TrialVolume 11, Issue 23, December 2018

JOURNAL:JACC Cardiovasc Interv. Article Link

Comparison of 2 Different Drug-Coated Balloons in In-Stent Restenosis: The RESTORE ISR China Randomized Trial

YD Chen, L Gao, Q Qin et al. Keywords: drug-coated balloon; drug-eluting stent(s); in-segment late loss; in-stent restenosis

ABSTRACT


OBJECTIVES - The aim of the present study was to evaluate the angiographic efficacy, clinical safety, and effectiveness of the Restore paclitaxel-coated balloon in a randomized trial designed to enable the approval of the new device in China.

 

BACKGROUND - Drug-coated balloon (DCB) angioplasty offers an effective treatment for in-stent restenosis. Restore is a new DCB with a SAFEPAX shellac-ammonium salt excipient that can avoid drug washing off during catheter delivery to the target lesion site.

 

METHODS -  In the noninferiority RESTORE ISR China (Compare the Efficacy and Safety of RESTORE DEB and SeQuent Please in Chinese Patient With Coronary In-stent Restenosis) trial, eligible patients with first occurrence of drug-eluting stent ISR were randomized to the Restore DCB or SeQuent Please DCB in a 1:1 ratio stratified by diabetes. Angiographic and clinical follow-up was planned at 9 months and 1 year, respectively, in all patients. The study was powered for the primary endpoint of 9-month in-segment late loss.

 

RESULTS - Between May 2016 and July 2017, a total of 240 subjects at 12 sites were randomized to either the Restore group (n = 120) or the SeQuent Please group (n = 120). Nine-month in-segment late loss was 0.38 ± 0.50 mm with Restore versus 0.35 ± 0.47 mm with SeQuent Please; the 1-sided 97.5% upper confidence limit of the difference was 0.17 mm, achieving noninferiority of Restore compared with SeQuent Please (p for noninferiority = 0.02). Both DCBs had similar 1-year rates of target lesion failure (13.3% vs. 12.6%; p = 0.87).

 

CONCLUSIONS - In this head-to-head randomized trial, the Restore DCB was noninferior to the SeQuent Please DCB for the primary endpoint of 9-month in-segment late loss. (Compare the Efficacy and Safety of RESTORE DEB and SeQuent Please in Chinese Patient With Coronary In-stent Restenosis; NCT02944890)