Development and validation of a simple risk score to predict 30-day readmission after percutaneous coronary intervention in a cohort of medicare patients Incidence, predictors, and outcomes of DAPT disruption due to non-compliance vs. bleeding after PCI: insights from the PARIS Registry Hs-cTroponins for the prediction of recurrent cardiovascular events in patients with established CHD - A comparative analysis from the KAROLA study Large-Bore Radial Access for Complex PCI: A Flash of COLOR With Some Shades of Grey Association of Coronary Anatomical Complexity With Clinical Outcomes After Percutaneous or Surgical Revascularization in the Veterans Affairs Clinical Assessment Reporting and Tracking Program Shock Team Approach in Refractory Cardiogenic Shock Requiring Short-Term Mechanical Circulatory Support: A Proof of Concept SCAI clinical expert consensus statement on the classification of cardiogenic shock: This document was endorsed by the American College of Cardiology (ACC), the American Heart Association (AHA), the Society of Critical Care Medicine (SCCM), and the Society of Thoracic Surgeons (STS) in April 2019 Mechanisms and diagnostic evaluation of persistent or recurrent angina following percutaneous coronary revascularization Prevalence, Presentation and Treatment of 'Balloon Undilatable' Chronic Total Occlusions: Insights from a Multicenter US Registry Dynamic Myocardial Ultrasound Localization Angiography

Clinical TrialVolume 11, Issue 23, December 2018

JOURNAL:JACC Cardiovasc Interv. Article Link

Comparison of 2 Different Drug-Coated Balloons in In-Stent Restenosis: The RESTORE ISR China Randomized Trial

YD Chen, L Gao, Q Qin et al. Keywords: drug-coated balloon; drug-eluting stent(s); in-segment late loss; in-stent restenosis

ABSTRACT


OBJECTIVES - The aim of the present study was to evaluate the angiographic efficacy, clinical safety, and effectiveness of the Restore paclitaxel-coated balloon in a randomized trial designed to enable the approval of the new device in China.

 

BACKGROUND - Drug-coated balloon (DCB) angioplasty offers an effective treatment for in-stent restenosis. Restore is a new DCB with a SAFEPAX shellac-ammonium salt excipient that can avoid drug washing off during catheter delivery to the target lesion site.

 

METHODS -  In the noninferiority RESTORE ISR China (Compare the Efficacy and Safety of RESTORE DEB and SeQuent Please in Chinese Patient With Coronary In-stent Restenosis) trial, eligible patients with first occurrence of drug-eluting stent ISR were randomized to the Restore DCB or SeQuent Please DCB in a 1:1 ratio stratified by diabetes. Angiographic and clinical follow-up was planned at 9 months and 1 year, respectively, in all patients. The study was powered for the primary endpoint of 9-month in-segment late loss.

 

RESULTS - Between May 2016 and July 2017, a total of 240 subjects at 12 sites were randomized to either the Restore group (n = 120) or the SeQuent Please group (n = 120). Nine-month in-segment late loss was 0.38 ± 0.50 mm with Restore versus 0.35 ± 0.47 mm with SeQuent Please; the 1-sided 97.5% upper confidence limit of the difference was 0.17 mm, achieving noninferiority of Restore compared with SeQuent Please (p for noninferiority = 0.02). Both DCBs had similar 1-year rates of target lesion failure (13.3% vs. 12.6%; p = 0.87).

 

CONCLUSIONS - In this head-to-head randomized trial, the Restore DCB was noninferior to the SeQuent Please DCB for the primary endpoint of 9-month in-segment late loss. (Compare the Efficacy and Safety of RESTORE DEB and SeQuent Please in Chinese Patient With Coronary In-stent Restenosis; NCT02944890)