CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Clinical applications of machine learning in the diagnosis, classification, and prediction of heart failure Rationale and design of the GUIDE-IT study: Guiding Evidence Based Therapy Using Biomarker Intensified Treatment in Heart Failure Comprehensive intravascular ultrasound assessment of stent area and its impact on restenosis and adverse cardiac events in 403 patients with unprotected left main disease Primary Prevention of Sudden Cardiac Death From Subclinical Atherosclerosis to Plaque Progression and Acute Coronary Events The year in cardiology: heart failure: The year in cardiology 2019 Association of Abnormal Left Ventricular Functional Reserve With Outcome in Heart Failure With Preserved Ejection Fraction Prevalence and clinical implications of valvular calcification on coronary computed tomography angiography Poor Long-Term Survival in Patients With Moderate Aortic Stenosis Percutaneous Atriotomy for Levoatrial–to–Coronary Sinus Shunting in Symptomatic Heart Failure: First-in-Human Experience

Original Research2018 Apr;33(2):146-153.

JOURNAL:Acta Cardiol Sin. Article Link

Tips of the dual-lumen microcatheter-facilitated reverse wire technique in percutaneous coronary interventions for markedly angulated bifurcated lesions

Nomura T, Kikai M, Hori Y et al. Keywords: bifurcation; dual-lumen microcatheter; reverse wire technique

ABSTRACT


In practical settings of percutaneous coronary intervention (PCI), we sometimes encounter difficulty in introducing a guidewire (GW) to the markedly angulated side branch (SB), and the reverse wire technique is considered as a last resort to overcome such a situation. We analyzed 12 cases that underwent PCI with dual-lumen microcatheter-facilitated reverse wire technique between January 2013 and July 2016. We retrospectively investigated the lesion's characteristics and the details of the PCI procedures, and discussed tips about the use of this technique. The SB that exhibits both a smaller take-off angle and a larger carina angle is considered to be the most suitable candidate for this technique. The first step of this technique involves the delivery of the reverse wire system to the target bifurcation. However, most cases exhibit significant stenosis proximal to the bifurcation, which often hampers the delivery of the reverse wire system. Because the sharply curved reverse wire system is easier to pass the stenosis as compared to the roundly curved system, we recommend a sharp curve should be adopted for this technique. On the other hand, it is sure that device delivery is much easier on the GW with a round curve as compared to that with a sharp curve. Therefore, it is important to modify the details of this procedure on a case-by-case basis according to the lesion's characteristics.