Mechanical complications of everolimus-eluting stents associated with adverse events: an intravascular ultrasound study Plaque composition by intravascular ultrasound and distal embolization after percutaneous coronary intervention The pyruvate-lactate axis modulates cardiac hypertrophy and heart failure Association of Smoking Status With Long‐Term Mortality and Health Status After Transcatheter Aortic Valve Replacement: Insights From the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry Cardiac Resynchronization Therapy in Inotrope-Dependent Heart Failure Patients - A Systematic Review and Meta-Analysis Circulating sST2 and catestatin levels in patients with acute worsening of heart failure: a report from the CATSTAT-HF study Meta-analysis of outcomes after intravascular ultrasound-guided versus angiography-guided drug-eluting stent implantation in 26,503 patients enrolled in three randomized trials and 14 observational studies Fluid Volume Overload and Congestion in Heart Failure: Time to Reconsider Pathophysiology and How Volume Is Assessed Role of Proximal Optimization Technique Guided by Intravascular Ultrasound on Stent Expansion, Stent Symmetry Index, and Side-Branch Hemodynamics in Patients With Coronary Bifurcation Lesions Optical frequency-domain imaging findings to predict good stent expansion after rotational atherectomy for severely calcified coronary lesions

Clinical TrialAugust 2017, Volume 10, Issue 8

JOURNAL:Circ Cardiovasc Interv. Article Link

Prognostic Value of Fractional Flow Reserve Measured Immediately After Drug-Eluting Stent Implantation

Piroth Z, Toth GG, De Bruyne B et al. Keywords: acute coronary syndromedrug-eluting stenthospitalizationmyocardial infarctionpercutaneous coronary intervention

ABSTRACT

Background The predictive value of fractional flow reserve (FFR) measured immediately after percutaneous coronary intervention (PCI) with drug-eluting stent placement has not been prospectively investigated. We investigated the potential of post-PCI FFR measurements to predict clinical outcome in patients from FAME 1 and 2 trials (Fractional Flow Reserve or Angiography for Multivessel Evaluation).

Methods and Results All patients of FAME 1 and FAME 2 who had post-PCI FFR measurement were included. The primary outcome was vessel-oriented composite end point at 2 years, defined as vessel-related cardiovascular death, vessel-related spontaneous myocardial infarction, and ischemia-driven target vessel revascularization. Eight hundred thirty-eight vessels in 639 patients were analyzed. Baseline FFR values did not differ between vessels with versus without vessel-oriented composite end point (0.66±0.11 versus 0.63±0.14, respectively; P=0.207). Post-PCI FFR was significantly lower in vessels with vessel-oriented composite end point (0.88±0.06 versus 0.90±0.06, respectively; P=0.019). Comparing the 2-year outcome of lower and upper tertiles of post-PCI FFR significant difference was found favoring upper tertile in terms of overall vessel-oriented composite end point (9.2% versus 3.8%, respectively; hazard ratio, 1.46; 95% confidence interval, 1.02–2.08; P=0.037) and target vessel revascularization (7.0% versus 2.4%, respectively; hazard ratio, 1.59; 95% confidence interval, 1.03–2.46; P=0.037). When adjusted to sex, hypertension, diabetes mellitus, target vessel, serial stenosis, and baseline percentage diameter stenosis, a strong trend was preserved in terms of target vessel revascularization (harzard ratio, 1.55; 95% confidence interval, 0.97–2.46; P=0.066), favoring the upper tertile. Post-PCI FFR of 0.92 was found to have the highest diagnostic accuracy; however, the positive likelihood ratio remained low (<1.4).

Conclusions A higher post-PCI FFR value is associated with a better vessel-related outcome. However, its predictive value is too low to advocate its use as a surrogate clinical end point.