CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Evolving insights into the role of local shear stress in late stent failure from neoatherosclerosis formation and plaque destabilization Venous and Arterial Thromboembolism in Patients With Cancer: JACC: CardioOncology State-of-the-Art Review Endoplasmic reticulum stress in doxorubicin-induced cardiotoxicity may be therapeutically targeted by natural and chemical compounds: A review 2020 ACC Expert Consensus Decision Pathway on Management of Bleeding in Patients on Oral Anticoagulants: A Report of the American College of Cardiology Solution Set Oversight Committee 2015 ACC/HRS/SCAI Left Atrial Appendage Occlusion Device Societal Overview 2022 ESC/ERS Guidelines for the diagnosis and treatment of pulmonary hypertension The Art of SAPIEN 3 Transcatheter Mitral Valve Replacement in Valve-in-Ring and Valve-in-Mitral-Annular-Calcification Procedures Functional Mitral Regurgitation Outcome and Grading in Heart Failure With Reduced Ejection Fraction Thirty-Day Outcomes Following Transfemoral Transseptal Transcatheter Mitral Valve Replacement: Intrepid TMVR Early Feasibility Study Results MITRA-FR vs. COAPT: Lessons from two trials with diametrically opposed results

Original Research2018 Nov 15;92(6):E416-E424.

JOURNAL:Catheter Cardiovasc Interv. Article Link

Long-term outcomes after treatment of bare-metal stent restenosis with paclitaxel-coated balloon catheters or everolimus-eluting stents: 3-year follow-up of the TIS clinical study

Pleva L, Kukla P, Zapletalova J et al. Keywords: everolimus-eluting stent; in-stent restenosis; paclitaxel-eluting balloon

ABSTRACT



BACKGROUND - The efficacy of paclitaxel-eluting balloon catheters (PEB) and drug-eluting stents for treatment of bare-metal stent restenosis (BMS-ISR) have been demonstrated in several studies with follow-up times of 9 to 12 months; however, the long-term outcomes of ISR treatment are less defined.


OBJECTIVES - We aimed to compare the long-term efficacy of PEB and everolimus-eluting stents (EES) for the treatment of BMS-ISR.


METHODS - We analyzed 3-year clinical follow-up data from patients included in the TIS randomized clinical study. A total of 136 patients with BMS-ISR were allocated to receive treatment with either PEB or EES (68 patients with 74 ISR lesions per group).


RESULTS - The PEB and EES groups did not significantly differ in major adverse cardiac events-free survival (MACE; P = .211; including individual events: CV death: P = .622; myocardial infarction: P = .650 or target vessel revascularization: P = .286) at 3-year clinical follow-up. No event-free survival differences were found between the groups regarding overall mortality (P = .818), definite stent thrombosis (P = .165) or the second MACE (P = .270).


CONCLUSIONS - At the 3-year follow-up, no significant differences in clinical outcomes were found between iopromide-coated PEB and EES for the treatment of BMS-ISR. (ClinicalTrials.gov; https://clinicaltrials.gov; NCT01735825).

© 2018 Wiley Periodicals, Inc.