CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Impact of Off-Hours Versus On-Hours Primary Percutaneous Coronary Intervention on Myocardial Damage and Clinical Outcomes in ST-Segment Elevation Myocardial Infarction The (R)Evolution of the CICU - Better for the Patient, Better for Education Canadian SCAD Cohort Study: Shedding Light on SCAD From a United Front Decreased inspired oxygen stimulates de novo formation of coronary collaterals in adult heart Selection of stenting approach for coronary bifurcation lesions BMI, Infarct Size, and Clinical Outcomes Following Primary PCI Patient-Level Analysis From 6 Randomized Trials Update in the Percutaneous Management of Coronary Chronic Total Occlusions Association of the PHACTR1/EDN1 Genetic Locus With Spontaneous Coronary Artery Dissection Clinical Practice Guideline for Screening and Management of High Blood Pressure in Children and Adolescents Reappraisal of Reported Genes for Sudden Arrhythmic Death: An Evidence-Based Evaluation of Gene Validity for Brugada Syndrome

Original Research2018 Nov 15;92(6):E416-E424.

JOURNAL:Catheter Cardiovasc Interv. Article Link

Long-term outcomes after treatment of bare-metal stent restenosis with paclitaxel-coated balloon catheters or everolimus-eluting stents: 3-year follow-up of the TIS clinical study

Pleva L, Kukla P, Zapletalova J et al. Keywords: everolimus-eluting stent; in-stent restenosis; paclitaxel-eluting balloon

ABSTRACT



BACKGROUND - The efficacy of paclitaxel-eluting balloon catheters (PEB) and drug-eluting stents for treatment of bare-metal stent restenosis (BMS-ISR) have been demonstrated in several studies with follow-up times of 9 to 12 months; however, the long-term outcomes of ISR treatment are less defined.


OBJECTIVES - We aimed to compare the long-term efficacy of PEB and everolimus-eluting stents (EES) for the treatment of BMS-ISR.


METHODS - We analyzed 3-year clinical follow-up data from patients included in the TIS randomized clinical study. A total of 136 patients with BMS-ISR were allocated to receive treatment with either PEB or EES (68 patients with 74 ISR lesions per group).


RESULTS - The PEB and EES groups did not significantly differ in major adverse cardiac events-free survival (MACE; P = .211; including individual events: CV death: P = .622; myocardial infarction: P = .650 or target vessel revascularization: P = .286) at 3-year clinical follow-up. No event-free survival differences were found between the groups regarding overall mortality (P = .818), definite stent thrombosis (P = .165) or the second MACE (P = .270).


CONCLUSIONS - At the 3-year follow-up, no significant differences in clinical outcomes were found between iopromide-coated PEB and EES for the treatment of BMS-ISR. (ClinicalTrials.gov; https://clinicaltrials.gov; NCT01735825).

© 2018 Wiley Periodicals, Inc.