CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Stent Thrombosis Risk Over Time on the Basis of Clinical Presentation and Platelet Reactivity: Analysis From ADAPT-DES Prognostic and Practical Validation of Current Definitions of Myocardial Infarction Associated With Percutaneous Coronary Intervention Galectin-3 Levels and Outcomes After Myocardial Infarction: A Population-Based Study Incidence and Outcomes of Acute Coronary Syndrome After Transcatheter Aortic Valve Replacement Antithrombotic Therapy in Patients With Atrial Fibrillation and Acute Coronary Syndrome High-Sensitivity Troponin and The Application of Risk Stratification Thresholds in Patients with Suspected Acute Coronary Syndrome Step-by-step manual for planning and performing bifurcation PCI: a resource-tailored approach Red Cell Distribution Width in Patients with Diabetes and Myocardial Infarction: an analysis from the EXAMINE trial Causes, Timing, and Impact of Dual Antiplatelet Therapy Interruption for Surgery (from the Patterns of Non-adherence to Anti-platelet Regimens In Stented Patients Registry) 2014 AHA/ACC Guideline for the Management of Patients with Non-ST-Elevation Acute Coronary Syndromes: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines

Original Research2018 Nov 15;92(6):E416-E424.

JOURNAL:Catheter Cardiovasc Interv. Article Link

Long-term outcomes after treatment of bare-metal stent restenosis with paclitaxel-coated balloon catheters or everolimus-eluting stents: 3-year follow-up of the TIS clinical study

Pleva L, Kukla P, Zapletalova J et al. Keywords: everolimus-eluting stent; in-stent restenosis; paclitaxel-eluting balloon

ABSTRACT



BACKGROUND - The efficacy of paclitaxel-eluting balloon catheters (PEB) and drug-eluting stents for treatment of bare-metal stent restenosis (BMS-ISR) have been demonstrated in several studies with follow-up times of 9 to 12 months; however, the long-term outcomes of ISR treatment are less defined.


OBJECTIVES - We aimed to compare the long-term efficacy of PEB and everolimus-eluting stents (EES) for the treatment of BMS-ISR.


METHODS - We analyzed 3-year clinical follow-up data from patients included in the TIS randomized clinical study. A total of 136 patients with BMS-ISR were allocated to receive treatment with either PEB or EES (68 patients with 74 ISR lesions per group).


RESULTS - The PEB and EES groups did not significantly differ in major adverse cardiac events-free survival (MACE; P = .211; including individual events: CV death: P = .622; myocardial infarction: P = .650 or target vessel revascularization: P = .286) at 3-year clinical follow-up. No event-free survival differences were found between the groups regarding overall mortality (P = .818), definite stent thrombosis (P = .165) or the second MACE (P = .270).


CONCLUSIONS - At the 3-year follow-up, no significant differences in clinical outcomes were found between iopromide-coated PEB and EES for the treatment of BMS-ISR. (ClinicalTrials.gov; https://clinicaltrials.gov; NCT01735825).

© 2018 Wiley Periodicals, Inc.