CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Bridging the Gap Between Epigenetic and Genetic in PAH Major Bleeding Rates in Atrial Fibrillation Patients on Single, Dual, or Triple Antithrombotic Therapy Risk of Mortality Following Catheter Ablation of Atrial Fibrillation Short- versus long-term duration of dual-antiplatelet therapy after coronary stenting: a randomized multicenter trial The year in cardiovascular medicine 2020: heart failure and cardiomyopathies Mediterranean Diet and the Association Between Air Pollution and Cardiovascular Disease Mortality Risk Sex Differences in Cardiovascular Pathophysiology: Why Women Are Overrepresented in Heart Failure With Preserved Ejection Fraction IVUS in bifurcation stenting: what have we learned? Efficacy of Ertugliflozin on Heart Failure–Related Events in Patients With Type 2 Diabetes Mellitus and Established Atherosclerotic Cardiovascular Disease Results of the VERTIS CV Trial Cardiovascular effects of radiation therapy

Original Research2018 Nov 15;92(6):E416-E424.

JOURNAL:Catheter Cardiovasc Interv. Article Link

Long-term outcomes after treatment of bare-metal stent restenosis with paclitaxel-coated balloon catheters or everolimus-eluting stents: 3-year follow-up of the TIS clinical study

Pleva L, Kukla P, Zapletalova J et al. Keywords: everolimus-eluting stent; in-stent restenosis; paclitaxel-eluting balloon

ABSTRACT



BACKGROUND - The efficacy of paclitaxel-eluting balloon catheters (PEB) and drug-eluting stents for treatment of bare-metal stent restenosis (BMS-ISR) have been demonstrated in several studies with follow-up times of 9 to 12 months; however, the long-term outcomes of ISR treatment are less defined.


OBJECTIVES - We aimed to compare the long-term efficacy of PEB and everolimus-eluting stents (EES) for the treatment of BMS-ISR.


METHODS - We analyzed 3-year clinical follow-up data from patients included in the TIS randomized clinical study. A total of 136 patients with BMS-ISR were allocated to receive treatment with either PEB or EES (68 patients with 74 ISR lesions per group).


RESULTS - The PEB and EES groups did not significantly differ in major adverse cardiac events-free survival (MACE; P = .211; including individual events: CV death: P = .622; myocardial infarction: P = .650 or target vessel revascularization: P = .286) at 3-year clinical follow-up. No event-free survival differences were found between the groups regarding overall mortality (P = .818), definite stent thrombosis (P = .165) or the second MACE (P = .270).


CONCLUSIONS - At the 3-year follow-up, no significant differences in clinical outcomes were found between iopromide-coated PEB and EES for the treatment of BMS-ISR. (ClinicalTrials.gov; https://clinicaltrials.gov; NCT01735825).

© 2018 Wiley Periodicals, Inc.