CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Intravascular Ultrasound and Angioscopy Assessment of Coronary Plaque Components in Chronic Totally Occluded Lesions Prior Balloon Valvuloplasty Versus Direct Transcatheter Aortic Valve Replacement: Results From the DIRECTAVI Trial Six-month versus 12-month dual antiplatelet therapy after implantation of drug-eluting stents: the Efficacy of Xience/Promus Versus Cypher to Reduce Late Loss After Stenting (EXCELLENT) randomized, multicenter study Transcatheter versus Surgical Aortic Valve Replacement in Patients with Prior Cardiac Surgery in the Randomized PARTNER 2A Trial Predictors of high residual gradient after transcatheter aortic valve replacement in bicuspid aortic valve stenosis Rationale and design of a large-scale, app-based study to identify cardiac arrhythmias using a smartwatch: The Apple Heart Study Novel predictors of late lumen enlargement in distal reference segments after successful recanalization of coronary chronic total occlusion Noninvasive Nuclear SPECT Myocardial Blood Flow Quantitation to Guide Management for Coronary Artery Disease Long-term effects of intensive glucose lowering on cardiovascular outcomes Chimney technique in a TAVR-in-TAVR procedure with high risk of left main artery ostium occlusion

Original Research2018 Jul;30(7):256-261.

JOURNAL: Article Link

Treatment of Very Small De Novo Coronary Artery Disease With 2.0 mm Drug-Coated Balloons Showed 1-Year Clinical Outcome Comparable With 2.0 mm Drug-Eluting Stents

Sim HW, Ananthakrishna R, Loh JP et al. Keywords: drug-coated balloon; drug-eluting stent; target-lesion failure

ABSTRACT


OBJECTIVE - To evaluate the 1-year clinical outcomes of patients treated with 2.0 mm drug-coated balloon (DCB) vs 2.0 mm drug-eluting stent (DES) implantation in small-caliber vessel de novo coronary artery disease (CAD).


METHODS - All patients treated with 2.0 mm DCB or 2.0 mm DES for very small vessel de novo CAD from July 2014 to June 2016 were included in this study. The primary endpoint was the occurrence of target-lesion failure (TLF) and time to TLF, defined as a combination of cardiac mortality, target-vessel myocardial infarction, and target-lesion revascularization (TLR).


RESULTS - A total of 87 patients (96 lesions) were implanted with 2.0 mm DCBs and 200 patients (223 lesions) were implanted with 2.0 mm DESs during the study period. Mean reference vessel diameter was similar between the DCB and DES groups (1.88 ± 0.38 mm vs 1.95 ± 0.21 mm, respectively; P=.11). The 1-year TLF rates were 7.0% in the DCB group and 8.2% in the DES group (P=.73). TLF was driven by TLR in both groups. Bailout stenting was performed in 7 patients (8 lesions) who received a DCB. Stent thrombosis was seen in 4 patients (2.0%) who underwent DES implantation. There was no vessel thrombosis noted in the DCB group. Cardiogenic shock was identified as a direct and significant predictor for both the occurrence of TLF and time to TLF.


CONCLUSIONS - In this first report, treatment of very small vessel CAD with 2.0 mm DCB vs 2.0 mm DES was associated with similar 1-year TLF rates.