CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Ticagrelor versus clopidogrel in elective percutaneous coronary intervention (ALPHEUS): a randomised, open-label, phase 3b trial Ticagrelor Monotherapy Versus Ticagrelor With Aspirin in Patients With ST-Segment Elevation Myocardial Infarction Dual-Antiplatelet Therapy Cessation and Cardiovascular Risk in Relation to Age: Analysis From the PARIS Registry Ticagrelor With or Without Aspirin in High-Risk Patients With Diabetes Mellitus Undergoing Percutaneous Coronary Intervention Low Endothelial Shear Stress Predicts Evolution to High-Risk Coronary Plaque Phenotype in the Future: A Serial Optical Coherence Tomography and Computational Fluid Dynamics Study Guideline Update on Indications for Transcatheter Aortic Valve Implantation Based on the 2020 American College of Cardiology/American Heart Association Guidelines for Management of Valvular Heart Disease Pooled Analysis of Bleeding, Major Adverse Cardiovascular Events, and All-Cause Mortality in Clinical Trials of Time-Constrained Dual-Antiplatelet Therapy After Percutaneous Coronary Intervention Stroke Complicating Infective Endocarditis After Transcatheter Aortic Valve Replacement Drug-eluting stent implantation in patients with acute coronary syndrome - the Activity of Platelets after Inhibition and Cardiovascular Events: Optical Coherence Tomography (APICE OCT) study Antithrombotic Management of Elderly Patients With Coronary Artery Disease

Original Research2018 Jul;30(7):256-261.

JOURNAL: Article Link

Treatment of Very Small De Novo Coronary Artery Disease With 2.0 mm Drug-Coated Balloons Showed 1-Year Clinical Outcome Comparable With 2.0 mm Drug-Eluting Stents

Sim HW, Ananthakrishna R, Loh JP et al. Keywords: drug-coated balloon; drug-eluting stent; target-lesion failure

ABSTRACT


OBJECTIVE - To evaluate the 1-year clinical outcomes of patients treated with 2.0 mm drug-coated balloon (DCB) vs 2.0 mm drug-eluting stent (DES) implantation in small-caliber vessel de novo coronary artery disease (CAD).


METHODS - All patients treated with 2.0 mm DCB or 2.0 mm DES for very small vessel de novo CAD from July 2014 to June 2016 were included in this study. The primary endpoint was the occurrence of target-lesion failure (TLF) and time to TLF, defined as a combination of cardiac mortality, target-vessel myocardial infarction, and target-lesion revascularization (TLR).


RESULTS - A total of 87 patients (96 lesions) were implanted with 2.0 mm DCBs and 200 patients (223 lesions) were implanted with 2.0 mm DESs during the study period. Mean reference vessel diameter was similar between the DCB and DES groups (1.88 ± 0.38 mm vs 1.95 ± 0.21 mm, respectively; P=.11). The 1-year TLF rates were 7.0% in the DCB group and 8.2% in the DES group (P=.73). TLF was driven by TLR in both groups. Bailout stenting was performed in 7 patients (8 lesions) who received a DCB. Stent thrombosis was seen in 4 patients (2.0%) who underwent DES implantation. There was no vessel thrombosis noted in the DCB group. Cardiogenic shock was identified as a direct and significant predictor for both the occurrence of TLF and time to TLF.


CONCLUSIONS - In this first report, treatment of very small vessel CAD with 2.0 mm DCB vs 2.0 mm DES was associated with similar 1-year TLF rates.