Evolving insights into the role of local shear stress in late stent failure from neoatherosclerosis formation and plaque destabilization Transseptal puncture versus patent foramen ovale or atrial septal defect access for left atrial appendage closure Functional Mitral Regurgitation Outcome and Grading in Heart Failure With Reduced Ejection Fraction Strain-Guided Management of Potentially Cardiotoxic Cancer Therapy Management and outcomes of patients with left atrial appendage thrombus prior to percutaneous closure Hemodynamic, Functional, and Clinical Responses to Pulmonary Artery Denervation in Patients With Pulmonary Arterial Hypertension of Different Causes Rivaroxaban for Thromboprophylaxis in High-Risk Ambulatory Patients With Cancer Long-Term Outcomes of Patients With Mediastinal Radiation–Associated Coronary Artery Disease Undergoing Coronary Revascularization With Percutaneous Coronary Intervention and Coronary Artery Bypass Grafting Implications of the local hemodynamic forces on the formation and destabilization of neoatherosclerotic lesions Potential Candidates for Transcatheter Tricuspid Valve Intervention After Transcatheter Aortic Valve Replacement: Predictors and Prognosis

Original Research2018 Jul;30(7):256-261.

JOURNAL: Article Link

Treatment of Very Small De Novo Coronary Artery Disease With 2.0 mm Drug-Coated Balloons Showed 1-Year Clinical Outcome Comparable With 2.0 mm Drug-Eluting Stents

Sim HW, Ananthakrishna R, Loh JP et al. Keywords: drug-coated balloon; drug-eluting stent; target-lesion failure

ABSTRACT


OBJECTIVE - To evaluate the 1-year clinical outcomes of patients treated with 2.0 mm drug-coated balloon (DCB) vs 2.0 mm drug-eluting stent (DES) implantation in small-caliber vessel de novo coronary artery disease (CAD).


METHODS - All patients treated with 2.0 mm DCB or 2.0 mm DES for very small vessel de novo CAD from July 2014 to June 2016 were included in this study. The primary endpoint was the occurrence of target-lesion failure (TLF) and time to TLF, defined as a combination of cardiac mortality, target-vessel myocardial infarction, and target-lesion revascularization (TLR).


RESULTS - A total of 87 patients (96 lesions) were implanted with 2.0 mm DCBs and 200 patients (223 lesions) were implanted with 2.0 mm DESs during the study period. Mean reference vessel diameter was similar between the DCB and DES groups (1.88 ± 0.38 mm vs 1.95 ± 0.21 mm, respectively; P=.11). The 1-year TLF rates were 7.0% in the DCB group and 8.2% in the DES group (P=.73). TLF was driven by TLR in both groups. Bailout stenting was performed in 7 patients (8 lesions) who received a DCB. Stent thrombosis was seen in 4 patients (2.0%) who underwent DES implantation. There was no vessel thrombosis noted in the DCB group. Cardiogenic shock was identified as a direct and significant predictor for both the occurrence of TLF and time to TLF.


CONCLUSIONS - In this first report, treatment of very small vessel CAD with 2.0 mm DCB vs 2.0 mm DES was associated with similar 1-year TLF rates.