Clinical and genetic characteristics of pulmonary arterial hypertension in Lebanon Deficiency of GATA3-Positive Macrophages Improves Cardiac Function Following Myocardial Infarction or Pressure Overload Hypertrophy Know Diabetes by Heart: A Partnership to Improve Cardiovascular Outcomes in Type 2 Diabetes Mellitus High-Sensitivity Troponin and The Application of Risk Stratification Thresholds in Patients with Suspected Acute Coronary Syndrome The Potential Use of the Index of Microcirculatory Resistance to Guide Stratification of Patients for Adjunctive Therapy in Acute Myocardial Infarction Imaging Coronary Anatomy and Reducing Myocardial Infarction Left Main Stenting: What We Have Learnt So Far? Effect of a Restrictive vs Liberal Blood Transfusion Strategy on Major Cardiovascular Events Among Patients With Acute Myocardial Infarction and Anemia: The REALITY Randomized Clinical Trial 2017 AHA/ACC Clinical Performance and Quality Measures for Adults With ST-Elevation and Non–ST-Elevation Myocardial Infarction: A Report of the American College of Cardiology/American Heart Association Task Force on Performance Measures Chronic Total Occlusion Percutaneous Coronary Intervention: Evidence and Controversies

Original Research2018 Jul;30(7):256-261.

JOURNAL: Article Link

Treatment of Very Small De Novo Coronary Artery Disease With 2.0 mm Drug-Coated Balloons Showed 1-Year Clinical Outcome Comparable With 2.0 mm Drug-Eluting Stents

Sim HW, Ananthakrishna R, Loh JP et al. Keywords: drug-coated balloon; drug-eluting stent; target-lesion failure

ABSTRACT


OBJECTIVE - To evaluate the 1-year clinical outcomes of patients treated with 2.0 mm drug-coated balloon (DCB) vs 2.0 mm drug-eluting stent (DES) implantation in small-caliber vessel de novo coronary artery disease (CAD).


METHODS - All patients treated with 2.0 mm DCB or 2.0 mm DES for very small vessel de novo CAD from July 2014 to June 2016 were included in this study. The primary endpoint was the occurrence of target-lesion failure (TLF) and time to TLF, defined as a combination of cardiac mortality, target-vessel myocardial infarction, and target-lesion revascularization (TLR).


RESULTS - A total of 87 patients (96 lesions) were implanted with 2.0 mm DCBs and 200 patients (223 lesions) were implanted with 2.0 mm DESs during the study period. Mean reference vessel diameter was similar between the DCB and DES groups (1.88 ± 0.38 mm vs 1.95 ± 0.21 mm, respectively; P=.11). The 1-year TLF rates were 7.0% in the DCB group and 8.2% in the DES group (P=.73). TLF was driven by TLR in both groups. Bailout stenting was performed in 7 patients (8 lesions) who received a DCB. Stent thrombosis was seen in 4 patients (2.0%) who underwent DES implantation. There was no vessel thrombosis noted in the DCB group. Cardiogenic shock was identified as a direct and significant predictor for both the occurrence of TLF and time to TLF.


CONCLUSIONS - In this first report, treatment of very small vessel CAD with 2.0 mm DCB vs 2.0 mm DES was associated with similar 1-year TLF rates.