CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Management of Antithrombotic Therapy in Atrial Fibrillation Patients Undergoing PCI: JACC State-of-the-Art Review 1-Year Outcomes After Edge-to-Edge Valve Repair for Symptomatic Tricuspid Regurgitation: Results From the TriValve Registry Long-term outcomes with use of intravascular ultrasound for the treatment of coronary bifurcation lesions Subclinical and Device-Detected Atrial Fibrillation: Pondering the Knowledge Gap: A Scientific Statement From the American Heart Association Anthracycline-induced cardiotoxicity: A multicenter randomised trial comparing two strategies for guiding prevention with enalapril: The International CardioOncology Society-one trial Clinical impact of conduction disturbances in transcatheter aortic valve replacement recipients: a systematic review and meta-analysis Current treatment of significant left main coronary artery disease: A review Genotyping to Guide Clopidogrel Treatment: An In-Depth Analysis of the TAILOR-PCI Trial Percutaneous Left Atrial Appendage Closure for Stroke Prophylaxis in Patients With Atrial Fibrillation: 2.3-Year Follow-up of the PROTECT AF (Watchman Left Atrial Appendage System for Embolic Protection in Patients With Atrial Fibrillation) Trial Role of intravascular ultrasound in patients with acute myocardial infarction undergoing percutaneous coronary intervention

Original Research2018 Jan 24;46(1):32-38.

JOURNAL:Zhonghua Xin Xue Guan Bing Za Zhi. Article Link

Therapeutic efficacy of paclitaxel-coated balloon for de novo coronary lesions with diameters larger than 2.8 mm

Yu X, Ji FS, Xu F et al. Keywords: oronary artery disease; Paclitaxel-eluting balloon; Treatment outcome

ABSTRACT


OBJECTIVE -  To evaluate the efficacy of paclitaxel-coated balloon for de novo coronary lesions with diameters 2.8 mm.

 

METHODS - This prospective study included 215 consecutive patients with 238 de novo lesions, who received paclitaxel-coated balloon angioplasty in Beijing Hospital from May 2014 to June 2016. According to the reference vessel diameter, the patients were divided into large vessel disease (LVD) group (reference vessel diameter2.8 mm, 85 patients and 90 lesions) and small vessel disease (SVD) group (reference vessel diameter<2.8 mm, 130 patients and 148 lesions). Clinical characteristics, interventional procedures and major adverse cardiovascular events (including all-cause mortality, non-fatal myocardial infarction and target lesion revascularization) after procedure were compared between the 2 groups.

 

RESULTS - (1)Patients in LVD group were younger than SVD group ((60.1±11.1) years old vs. (65.0±10.6) years old, P<0.01), and less patients had diabetes (24.7% (21/85) vs. 43.1%(56/130), P<0.01).(2)Prevalence of three-vessel disease (35.5%(30/85) vs. 53.6%(67/130), P<0.05) and complex lesions (type B2/C,34.4% (31/90) vs. 50.0%(74/148), P<0.05) were significantly lower in LVD group than in SVD group.(3) During pre-dilation, the rate with plain balloons use was significantly higher in SVD group than in LVD group(76.4%(113/148) vs. 58.9%(53/90), P<0.01), while the proportion of additional use of non-compliant balloons was significantly higher in LVD groupthan in SVD group(20.0% (18/90) vs. 3.4% (5/148) , P<0.01). The ratio of paclitaxel-coated balloon diameter/RVD was significantly lower (0.87±0.12 vs. 0.96±0.15, P<0.01) and the duration of dilationwas significantly shorter ((41.5±9.5) seconds vs. (45.1±9.1) seconds, P<0.01) in LVD group than those in SVD group. Each group had 1 failure case that was bailout stented with drug-eluting stents. The success rate of paclitaxel-coated balloon treatment was similar in LVD group and SVD group (98.9% (89/90) vs. 99.3%(147/148), P>0.05).(4) At the fourth day of procedure, there was 1 acute myocardial infarction requiring emergent target lesion revascularization in SVD group. No major adverse cardiovascular event was observed in LVD group during hospitalization. Forty-two patients with 53 lesions, including 27 LVD lesions and 26 SVD lesions,underwent coronary angiography at (9.4±4.6) months after paclitaxel-coated balloon intervention. The quantitative coronary angiography analysis showed that minimal lumen diameter significantlyincreased during follow-up than that of post-procedurein SVD group ((1.71±0.36)mm vs. (1.52±0.30)mm, P<0.05) , while in LVD group the minimal lumen diameter was similar between during follow-up and post-procedure ((2.35±0.48)mm vs. (2.19±0.34)mm, P>0.05). Major adverse cardiovascular event rate was 0 in LVD group and 2.3%(3/130) in SVD group (P>0.05) during follow up. No death was observed in this patient cohort.

 

CONCLUSIONS - Treatment with paclitaxel-coated balloon for de novo coronary lesions with diameters 2.8 mm is safe and effective.