Validation of bifurcation DEFINITION criteria and comparison of stenting strategies in true left main bifurcation lesions Will Pulmonary Artery Denervation Really Have a Place in the Armamentarium of the Pulmonary Hypertension Specialist? Long-term secondary prevention of cardiovascular disease with a Mediterranean diet and a low-fat diet (CORDIOPREV): a randomised controlled trial High-Resolution Cardiac Magnetic Resonance Imaging Techniques for the Identification of Coronary Microvascular Dysfunction Diagnostic Performance of Angiogram-Derived Fractional Flow Reserve: A Pooled Analysis of 5 Prospective Cohort Studies Intravascular optical coherence tomography Patient and Hospital Characteristics of Mitral Valve Surgery in the United States Angiography Alone Versus Angiography Plus Optical Coherence Tomography to Guide Percutaneous Coronary Intervention Outcomes From the Pan-London PCI Cohort New Volumetric Analysis Method for Stent Expansion and its Correlation With Final Fractional Flow Reserve and Clinical Outcome An ILUMIEN I Substudy The EBC TWO Study (European Bifurcation Coronary TWO): A Randomized Comparison of Provisional T-Stenting Versus a Systematic 2 Stent Culotte Strategy in Large Caliber True Bifurcations

Original Research2018 Jan 24;46(1):32-38.

JOURNAL:Zhonghua Xin Xue Guan Bing Za Zhi. Article Link

Therapeutic efficacy of paclitaxel-coated balloon for de novo coronary lesions with diameters larger than 2.8 mm

Yu X, Ji FS, Xu F et al. Keywords: oronary artery disease; Paclitaxel-eluting balloon; Treatment outcome

ABSTRACT


OBJECTIVE -  To evaluate the efficacy of paclitaxel-coated balloon for de novo coronary lesions with diameters 2.8 mm.

 

METHODS - This prospective study included 215 consecutive patients with 238 de novo lesions, who received paclitaxel-coated balloon angioplasty in Beijing Hospital from May 2014 to June 2016. According to the reference vessel diameter, the patients were divided into large vessel disease (LVD) group (reference vessel diameter2.8 mm, 85 patients and 90 lesions) and small vessel disease (SVD) group (reference vessel diameter<2.8 mm, 130 patients and 148 lesions). Clinical characteristics, interventional procedures and major adverse cardiovascular events (including all-cause mortality, non-fatal myocardial infarction and target lesion revascularization) after procedure were compared between the 2 groups.

 

RESULTS - (1)Patients in LVD group were younger than SVD group ((60.1±11.1) years old vs. (65.0±10.6) years old, P<0.01), and less patients had diabetes (24.7% (21/85) vs. 43.1%(56/130), P<0.01).(2)Prevalence of three-vessel disease (35.5%(30/85) vs. 53.6%(67/130), P<0.05) and complex lesions (type B2/C,34.4% (31/90) vs. 50.0%(74/148), P<0.05) were significantly lower in LVD group than in SVD group.(3) During pre-dilation, the rate with plain balloons use was significantly higher in SVD group than in LVD group(76.4%(113/148) vs. 58.9%(53/90), P<0.01), while the proportion of additional use of non-compliant balloons was significantly higher in LVD groupthan in SVD group(20.0% (18/90) vs. 3.4% (5/148) , P<0.01). The ratio of paclitaxel-coated balloon diameter/RVD was significantly lower (0.87±0.12 vs. 0.96±0.15, P<0.01) and the duration of dilationwas significantly shorter ((41.5±9.5) seconds vs. (45.1±9.1) seconds, P<0.01) in LVD group than those in SVD group. Each group had 1 failure case that was bailout stented with drug-eluting stents. The success rate of paclitaxel-coated balloon treatment was similar in LVD group and SVD group (98.9% (89/90) vs. 99.3%(147/148), P>0.05).(4) At the fourth day of procedure, there was 1 acute myocardial infarction requiring emergent target lesion revascularization in SVD group. No major adverse cardiovascular event was observed in LVD group during hospitalization. Forty-two patients with 53 lesions, including 27 LVD lesions and 26 SVD lesions,underwent coronary angiography at (9.4±4.6) months after paclitaxel-coated balloon intervention. The quantitative coronary angiography analysis showed that minimal lumen diameter significantlyincreased during follow-up than that of post-procedurein SVD group ((1.71±0.36)mm vs. (1.52±0.30)mm, P<0.05) , while in LVD group the minimal lumen diameter was similar between during follow-up and post-procedure ((2.35±0.48)mm vs. (2.19±0.34)mm, P>0.05). Major adverse cardiovascular event rate was 0 in LVD group and 2.3%(3/130) in SVD group (P>0.05) during follow up. No death was observed in this patient cohort.

 

CONCLUSIONS - Treatment with paclitaxel-coated balloon for de novo coronary lesions with diameters 2.8 mm is safe and effective.