CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Aspirin in the primary and secondary prevention of vascular disease: collaborative meta-analysis of individual participant data from randomised trials Transverse partial stent ablation with rotational atherectomy for suboptimal culotte technique in left main stem bifurcation Glucose-lowering Drugs or Strategies, Atherosclerotic Cardiovascular Events, and Heart Failure in People With or at Risk of Type 2 Diabetes: An Updated Systematic Review and Meta-Analysis of Randomised Cardiovascular Outcome Trials Genetics and Causality of Triglyceride-Rich Lipoproteins in Atherosclerotic Cardiovascular Disease The Current State of Left Main Percutaneous Coronary Intervention Potential protective mechanisms of green tea polyphenol EGCG against COVID-19 Effect of empagliflozin on exercise ability and symptoms in heart failure patients with reduced and preserved ejection fraction, with and without type 2 diabetes Radial Versus Femoral Access for Rotational Atherectomy: A UK Observational Study of 8622 Patients The outcomes of intravascular ultrasound-guided drug-eluting stent implantation among patients with complex coronary lesions: a comprehensive meta-analysis of 15 clinical trials and 8,084 patients Limitations of Repeat Revascularization as an Outcome Measure

Original Research2018 Jan 24;46(1):32-38.

JOURNAL:Zhonghua Xin Xue Guan Bing Za Zhi. Article Link

Therapeutic efficacy of paclitaxel-coated balloon for de novo coronary lesions with diameters larger than 2.8 mm

Yu X, Ji FS, Xu F et al. Keywords: oronary artery disease; Paclitaxel-eluting balloon; Treatment outcome

ABSTRACT


OBJECTIVE -  To evaluate the efficacy of paclitaxel-coated balloon for de novo coronary lesions with diameters 2.8 mm.

 

METHODS - This prospective study included 215 consecutive patients with 238 de novo lesions, who received paclitaxel-coated balloon angioplasty in Beijing Hospital from May 2014 to June 2016. According to the reference vessel diameter, the patients were divided into large vessel disease (LVD) group (reference vessel diameter2.8 mm, 85 patients and 90 lesions) and small vessel disease (SVD) group (reference vessel diameter<2.8 mm, 130 patients and 148 lesions). Clinical characteristics, interventional procedures and major adverse cardiovascular events (including all-cause mortality, non-fatal myocardial infarction and target lesion revascularization) after procedure were compared between the 2 groups.

 

RESULTS - (1)Patients in LVD group were younger than SVD group ((60.1±11.1) years old vs. (65.0±10.6) years old, P<0.01), and less patients had diabetes (24.7% (21/85) vs. 43.1%(56/130), P<0.01).(2)Prevalence of three-vessel disease (35.5%(30/85) vs. 53.6%(67/130), P<0.05) and complex lesions (type B2/C,34.4% (31/90) vs. 50.0%(74/148), P<0.05) were significantly lower in LVD group than in SVD group.(3) During pre-dilation, the rate with plain balloons use was significantly higher in SVD group than in LVD group(76.4%(113/148) vs. 58.9%(53/90), P<0.01), while the proportion of additional use of non-compliant balloons was significantly higher in LVD groupthan in SVD group(20.0% (18/90) vs. 3.4% (5/148) , P<0.01). The ratio of paclitaxel-coated balloon diameter/RVD was significantly lower (0.87±0.12 vs. 0.96±0.15, P<0.01) and the duration of dilationwas significantly shorter ((41.5±9.5) seconds vs. (45.1±9.1) seconds, P<0.01) in LVD group than those in SVD group. Each group had 1 failure case that was bailout stented with drug-eluting stents. The success rate of paclitaxel-coated balloon treatment was similar in LVD group and SVD group (98.9% (89/90) vs. 99.3%(147/148), P>0.05).(4) At the fourth day of procedure, there was 1 acute myocardial infarction requiring emergent target lesion revascularization in SVD group. No major adverse cardiovascular event was observed in LVD group during hospitalization. Forty-two patients with 53 lesions, including 27 LVD lesions and 26 SVD lesions,underwent coronary angiography at (9.4±4.6) months after paclitaxel-coated balloon intervention. The quantitative coronary angiography analysis showed that minimal lumen diameter significantlyincreased during follow-up than that of post-procedurein SVD group ((1.71±0.36)mm vs. (1.52±0.30)mm, P<0.05) , while in LVD group the minimal lumen diameter was similar between during follow-up and post-procedure ((2.35±0.48)mm vs. (2.19±0.34)mm, P>0.05). Major adverse cardiovascular event rate was 0 in LVD group and 2.3%(3/130) in SVD group (P>0.05) during follow up. No death was observed in this patient cohort.

 

CONCLUSIONS - Treatment with paclitaxel-coated balloon for de novo coronary lesions with diameters 2.8 mm is safe and effective.