CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Targeting the Immune System in Atherosclerosis: JACC State-of-the-Art Review Low-Dose Aspirin Discontinuation and Risk of Cardiovascular Events: A Swedish Nationwide, Population-Based Cohort Study Bare metal versus drug eluting stents for ST-segment elevation myocardial infarction in the TOTAL trial Door to Balloon Time: Is There a Point That Is Too Short? Comparison of Outcomes of Patients With ST-Segment Elevation Myocardial Infarction Treated by Primary Percutaneous Coronary Intervention Analyzed by Age Groups (<75, 75 to 85, and >85 Years); (Results from the Bremen STEMI Registry) Nonculprit Stenosis Evaluation Using Instantaneous Wave-Free Ratio in Patients With ST-Segment Elevation Myocardial Infarction Location of the culprit coronary lesion and its association with delay in door-to-balloon time (from a multicenter registry of primary percutaneous coronary intervention) Volume brings value Percutaneous coronary intervention reduces mortality in myocardial infarction patients with comorbidities: Implications for elderly patients with diabetes or kidney disease Remote ischaemic conditioning and healthcare system delay in patients with ST-segment elevation myocardial infarction

January 2019

JOURNAL:JACC: Clinical Electrophysiology Article Link

Wearable Cardioverter-Defibrillator Therapy for the Prevention of Sudden Cardiac Death A Systematic Review and Meta-Analysis

A Masri, AM Altibi, S Erqou et al. Keywords: death; meta-analysis; shock; systematic review; wearable cardioverter-defibrillator

ABSTRACT

OBJECTIVES - This study sought to synthesize the available evidence on the use of the wearable cardioverter-defibrillator (WCD).


BACKGROUND - Observational WCD studies for the prevention of sudden cardiac death have provided conflicting data. The VEST (Vest Prevention of Early Sudden Death) trial was the first randomized controlled trial (RCT) showing no reduction in sudden cardiac death as compared to medical therapy only.


METHODS - We searched PubMed, EMBASE, and Google Scholar for studies reporting on the outcomes of patients wearing WCDs from January 1, 2001, through March 20, 2018. Rates of appropriate and inappropriate WCD therapies were pooled. Estimates were derived using DerSimonian and Lairds method.


RESULTS - Twenty-eight studies were included (N = 33,242; 27 observational, 1 RCT-WCD arm). The incidence of appropriate WCD therapy was 5 per 100 persons over 3 months (95% confidence interval [CI]: 3.0 to 6.0, I2 = 93%). In studies on ischemic cardiomyopathy, the appropriate WCD therapy incidence was lower in the VEST trial (1 per 100 persons over 3 months; 95% CI: 1.0 to 2.0) as compared with observational studies (11 per 100 persons over 3 months; 95% CI: 11.0 to 20.0; I2 = 93%). The incidence of inappropriate therapy was 2 per 100 persons over 3 months (95% CI: 1.0 to 3.0; I2 = 93%). Mortality while wearing WCD was rare at 0.7 per 100 persons over 3 months (95% CI: 0.3 to 1.7; I2 = 94%).


CONCLUSIONS - The rate of appropriately treated WCD patients over 3 months of follow-up was substantial; higher in-observational studies as compared with the VEST trial. There was significant heterogeneity. More RCTs are needed to justify continued use of WCD in primary prevention.