2019 AHA/ACC/HRS Focused Update of the 2014 AHA/ACC/HRS Guideline for the Management of Patients With Atrial Fibrillation: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines and the Heart Rhythm Society Association of Plaque Location and Vessel Geometry Determined by Coronary Computed Tomographic Angiography With Future Acute Coronary Syndrome–Causing Culprit Lesions Screening for Atrial Fibrillation With ECG: USPSTF Recommendation Subclinical Atherosclerosis Burden by 3D Ultrasound in Mid-Life: The PESA Study Risk Stratification Guided by the Index of Microcirculatory Resistance and Left Ventricular End-Diastolic Pressure in Acute Myocardial Infarction Coronary Catheterization and Percutaneous Coronary Intervention in China: 10-Year Results From the China PEACE-Retrospective CathPCI Study Effect of improved door-to-balloon time on clinical outcomes in patients with ST segment elevation myocardial infarction Robotics in percutaneous cardiovascular interventions Long-Term Outcomes in Women and Men Following Percutaneous Coronary Intervention A prospective, randomised trial of transapical transcatheter aortic valve implantation vs. surgical aortic valve replacement in operable elderly patients with aortic stenosis: the STACCATO trial

January 2019

JOURNAL:JACC: Clinical Electrophysiology Article Link

Wearable Cardioverter-Defibrillator Therapy for the Prevention of Sudden Cardiac Death A Systematic Review and Meta-Analysis

A Masri, AM Altibi, S Erqou et al. Keywords: death; meta-analysis; shock; systematic review; wearable cardioverter-defibrillator

ABSTRACT

OBJECTIVES - This study sought to synthesize the available evidence on the use of the wearable cardioverter-defibrillator (WCD).


BACKGROUND - Observational WCD studies for the prevention of sudden cardiac death have provided conflicting data. The VEST (Vest Prevention of Early Sudden Death) trial was the first randomized controlled trial (RCT) showing no reduction in sudden cardiac death as compared to medical therapy only.


METHODS - We searched PubMed, EMBASE, and Google Scholar for studies reporting on the outcomes of patients wearing WCDs from January 1, 2001, through March 20, 2018. Rates of appropriate and inappropriate WCD therapies were pooled. Estimates were derived using DerSimonian and Lairds method.


RESULTS - Twenty-eight studies were included (N = 33,242; 27 observational, 1 RCT-WCD arm). The incidence of appropriate WCD therapy was 5 per 100 persons over 3 months (95% confidence interval [CI]: 3.0 to 6.0, I2 = 93%). In studies on ischemic cardiomyopathy, the appropriate WCD therapy incidence was lower in the VEST trial (1 per 100 persons over 3 months; 95% CI: 1.0 to 2.0) as compared with observational studies (11 per 100 persons over 3 months; 95% CI: 11.0 to 20.0; I2 = 93%). The incidence of inappropriate therapy was 2 per 100 persons over 3 months (95% CI: 1.0 to 3.0; I2 = 93%). Mortality while wearing WCD was rare at 0.7 per 100 persons over 3 months (95% CI: 0.3 to 1.7; I2 = 94%).