CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Local Low Shear Stress and Endothelial Dysfunction in Patients With Nonobstructive Coronary Atherosclerosis Management of pulmonary hypertension from left heart disease in candidates for orthotopic heart transplantation One Versus 2-stent Strategy for the Treatment of Bifurcation Lesions in the Context of a Coronary Chronic Total Occlusion: A Multicenter Registry Classification and treatment of coronary artery bifurcation lesions: putting the Medina classification to the test Left ventricular remodelling and changes in functional measurements in patients undergoing transcatheter vs surgical aortic valve replacement: a head-to-head comparison Coronary fractional flow reserve in bifurcation stenoses: what have we learned? Diagnostic accuracy of intracoronary optical coherence tomography-derived fractional flow reserve for assessment of coronary stenosis severity T and small protrusion (TAP) vs double kissing crush technique: Insights from in-vitro models ‘Small bifurcation?’ CT myocardial mass volume measurements change therapeutic strategy in coronary artery disease Therapeutic efficacy of paclitaxel-coated balloon for de novo coronary lesions with diameters larger than 2.8 mm

Clinical Trial2017 Oct 23;10(20):2029-2037

JOURNAL:JACC Cardiovasc Interv. Article Link

The SABRE Trial (Sirolimus Angioplasty Balloon for Coronary In-Stent Restenosis): Angiographic Results and 1-Year Clinical Outcomes

Verheye S, Vrolix M, Kumsars I et al. Keywords: drug-eluting balloon; extended release; in-stent restenosis; porous angioplasty balloon; sirolimus nanoparticle

ABSTRACT



OBJECTIVES - The aim of this first-in-human study was to assess the safety and effectiveness of the Virtue sirolimus-eluting balloon in a cohort of patients with in-stent restenosis (ISR).


BACKGROUND - Angioplasty balloons coated with the cytotoxic drug paclitaxel have been widely used for ISR treatment. The Virtue angioplasty balloon (Caliber Therapeutics, New Hope, Pennsylvania) delivers sirolimus in a nanoencapsulated liquid formulation. This clinical trial is the first to examine a sirolimus-eluting balloon for ISR.


METHODS - In this prospective, single-arm feasibility study at 9 European centers, 50 ISR patients were treated with the Virtue balloon. Angiographic measurements at 6 months are reported, along with 12-month clinicalfollow-up.


RESULTS - Procedural success in the intention-to-treat population was 100%. The primary safety endpoint was target lesion failure (TLF) (cardiac death, target vessel myocardial infarction, and clinically driven target lesion revascularization) assessed at 30 days (0%, n = 50). The primary performance endpoint was in-segment late lumen loss (LLL) at 6 months (0.31 ± 0.52 mm; n = 47). Secondary 6-month endpoints include binary restenosis (19.1%), diameter stenosis (30.3 ± 19.9%), and major adverse cardiac events (MACE) (10.2%, n = 49). In the 36-patient per-protocol population (excluding major protocol violations and previously stented ISR), LLL was 0.12 ± 0.33 mm at 6 months. Clinical outcomes at 1 year for the intention-to-treat group were 12.2% TLF and 14.3% MACE and for the per-protocol population were 2.8% TLF and 2.8% MACE.


CONCLUSIONS - This first-in-human study showed excellent procedural success for the Virtue sirolimus-eluting angioplasty balloon, 6-month LLL rates in line with current stent-free ISR treatment options, and clinicaloutcomes that warrant further evaluation in dedicated randomized studies.


Copyright © 2017 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.