CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Atrial Fibrillation and the Prognostic Performance of Biomarkers in Heart Failure Dapagliflozin and Cardiovascular Outcomes in Type 2 Diabetes Meta-analysis of outcomes after intravascular ultrasound-guided versus angiography-guided drug-eluting stent implantation in 26,503 patients enrolled in three randomized trials and 14 observational studies Mechanical circulatory support devices for acute right ventricular failure Association of Left Ventricular Systolic Function With Incident Heart Failure in Late Life Pulmonary artery denervation to treat pulmonary arterial hypertension: the single-center, prospective, first-in-man PADN-1 study (first-in-man pulmonary artery denervation for treatment of pulmonary artery hypertension) Age-Related Characteristics and Outcomes of Patients With Heart Failure With Preserved Ejection Fraction In patients with stable coronary heart disease, low-density lipoprotein-cholesterol levels < 70 mg/dL and glycosylated hemoglobin A1c < 7% are associated with lower major cardiovascular events Mechanical circulatory support devices in advanced heart failure: 2020 and beyond Efficacy and Safety of Dapagliflozin in Heart Failure With Reduced Ejection Fraction According to Age: Insights From DAPA-HF

Clinical Trial2016 Apr;176(4):512-21

JOURNAL:JAMA Intern Med. Article Link

Coronary Catheterization and Percutaneous Coronary Intervention in China: 10-Year Results From the China PEACE-Retrospective CathPCI Study

Zheng X, Curtis JP, China PEACE Collaborative Gro Keywords: coronary artery; percutaneous coronary intervention; trend;quality of care

ABSTRACT


IMPORTANCE - The use of coronary catheterization and percutaneous coronary intervention (PCI) is increasing in China, but, to date, there are no nationally representative assessments of the quality of care and outcomes in patients undergoing these procedures.


OBJECTIVE - To assess the quality of care and outcomes of patients undergoing coronary catheterization and PCI in China.


DESIGN, SETTING, AND PARTICIPANTS - In a clinical observational study (China PEACE [Patient-Centered Evaluative Assessment of Cardiac Events]-Retrospective CathPCI Study), we used a 2-stage, random sampling strategy to create a nationally representative sample of 11 241 patients undergoing coronary catheterization and PCI at 55 urban Chinese hospitals in calendar years 2001, 2006, and 2011. Data analysis was performed from July 11, 2014, to November 20, 2015.


MAIN OUTCOMES AND MEASURES - Patient characteristics, treatment patterns, quality of care, and outcomes associated with these procedures and changes over time.


RESULTS - Of the 11 241 patients included in the study, the samples included, for 2001, 285 women (weighted percentage, 28.6%); for 2006, 826 women (weighted percentage, 32.2%), and for 2011, 2588 women (weighted percentage, 35.7%). Mean (SD) ages were 58 (8), 60 (11), and 61 (11) years, respectively. Between 2001 and 2011, estimated national rates of hospitalizations for coronary catheterization increased from 26 570 to 452 784 and for PCI, from 9678 to 208 954 (17-fold and 21-fold), respectively. More than half of stable patients undergoing coronary catheterization had nonobstructive coronary artery disease; this amount did not change significantly over time (2001: 60.3% [95% CI, 56.1%-64.5%]; 2011: 57.5% [95% CI, 55.8%-59.3%], P = .05 for trend). The proportion of PCI procedures performed via radial approach increased from 3.5% (95% CI, 1.7%-5.3%) in 2001 to 79.0% (95% CI, 77.7%-80.3%) in 2011 (P < . 001 for trend). The use of drug-eluting stents (DESs) increased from 18.0% (95% CI, 14.2%-21.7%) in 2001 to 97.3% (95% CI, 96.9%-97.7%) in 2011 (P < .001 for trend) largely owing to increased use of domestic DESs. The median length of stay decreased from 14 days (interquartile range [IQR], 9-20) in 2001 to 10 days (IQR, 7-14) in 2011 (P < .001 for trend). In-hospital mortality did not change significantly, but both adjusted risk of any bleeding (odds ratio [OR], 0.53 [95% CI, 0.36-0.79], P < .001 for trend) and access bleeding (OR, 0.23 [95% CI, 0.12-0.43], P < .001) were decreased between 2001 and 2011. The medical records lacked documentation needed to calculate commonly used process metrics including door to balloon times for primary PCI and the prescription of evidence-based medications at discharge.


CONCLUSIONS AND RELEVANCE - Although the use of catheterization and PCI in China has increased dramatically, we identified critical quality and documentation gaps that represent opportunities to improve care. Our findings can serve as a foundation to guide future quality improvement initiatives in China.