CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Valve‐in‐Valve for Degenerated Transcatheter Aortic Valve Replacement Versus Valve‐in‐Valve for Degenerated Surgical Aortic Bioprostheses: A 3‐Center Comparison of Hemodynamic and 1‐Year Outcome Individualized antiplatelet therapy after drug-eluting stent deployment: Implication of clinical trials of different durations of dual antiplatelet therapy 2021 ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure Complex PCI procedures: challenges for the interventional cardiologist The role of integrated backscatter intravascular ultrasound in characterizing bare metal and drug-eluting stent restenotic neointima as compared to optical coherence tomography Intravascular ultrasound predictors of angiographic restenosis after sirolimus-eluting stent implantation Value of Coronary Artery Calcium Scanning in Association With the Net Benefit of Aspirin in Primary Prevention of Atherosclerotic Cardiovascular Disease Clinical Outcomes Following Intravascular Imaging-Guided Versus Coronary Angiography-Guided Percutaneous Coronary Intervention With Stent Implantation: A Systematic Review and Bayesian Network Meta-Analysis of 31 Studies and 17,882 Patients Intravascular Ultrasound Guidance vs. Angiographic Guidance in Primary Percutaneous Coronary Intervention for ST-Segment Elevation Myocardial Infarction - Long-Term Clinical Outcomes From the CREDO-Kyoto AMI Registry Differential Impact of Heart Failure With Reduced Ejection Fraction on Men and Women

Clinical Trial2017 Oct 23;10(20):2113-2123

JOURNAL:JACC Cardiovasc Interv. Article Link

Drug-Coated Balloon Treatment for Femoropopliteal Artery Disease: The IN.PACT Global Study De Novo In-Stent Restenosis Imaging Cohort

Brodmann M, Keirse K, IN.PACT Global Study Investigators Keywords: drug-coated balloon; femoropopliteal artery; in-stent restenosis; paclitaxel; peripheral artery disease

ABSTRACT


OBJECTIVES - This study sought to evaluate the safety and effectiveness of a paclitaxel-coated drug-coatedballoon (DCB) for the treatment of patients with de novo in-stent restenosis (ISR).


BACKGROUND - Treatment of patients with ISR remains a challenge. Current strategies are plagued by high rates of recurrent restenosis and need for reintervention. The best intervention for ISR remains to be elucidated.


METHODS - The IN.PACT Global study is an independently adjudicated multicenter, prospective, single-arm study that enrolled 1,535 subjects with symptomatic atherosclerotic disease of the superficial femoral and/or popliteal arteries, including de novo ISR lesions. Patients enrolled in the pre-specified ISR imaging cohort were evaluated for vessel patency and reintervention within the 12-month follow-up period.


RESULTS - A total of 131 subjects with 149 ISR lesions were included for analysis. The mean age of the cohort was 67.8 years. Mean lesion length was 17.17 ± 10.47 cm, including 34.0% total occlusions and 59.1% calcified lesions. The 12-month Kaplan-Meier estimate of primary patency was 88.7%. The rate of clinically driven target lesion revascularization (CD TLR) at 12 months was 7.3%. The primary safety outcome, a composite of freedom from device- and procedure-related mortality through 30 days and freedom from major target limb amputation and CD TLR within 12 months, was 92.7%. There were no major target limb amputations, no deaths, and a low (0.8%) thrombosis rate.


CONCLUSIONS - Results from the ISR imaging cohort demonstrate high patency and a low rate of CD TLR at 12 months. These data confirm the safety and effectiveness of the IN.PACT Admiral DCB (Medtronic, Dublin, Ireland) in complex femoropopliteal lesions, including this challenging subset.

Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.