CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Routinely reported ejection fraction and mortality in clinical practice: where does the nadir of risk lie? 2016 ACC/AHA/HFSA Focused Update on New Pharmacological Therapy for Heart Failure: An Update of the 2013 ACCF/AHA Guideline for the Management of Heart Failure: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines and the Heart Failure State of the Art in Noninvasive Imaging of Ischemic Heart Disease and Coronary Microvascular Dysfunction in Women: Indications, Performance, and Limitations Hs-cTroponins for the prediction of recurrent cardiovascular events in patients with established CHD - A comparative analysis from the KAROLA study Comparative Effectiveness of β-Blocker Use Beyond 3 Years After Myocardial Infarction and Long-Term Outcomes Among Elderly Patients Novel functions of macrophages in the heart: insights into electrical conduction, stress, and diastolic dysfunction Dynamic atrioventricular delay programming improves ventricular electrical synchronization as evaluated by 3D vectorcardiography Drug-Coated Balloon Versus Drug-Eluting Stent in Primary Percutaneous Coronary Intervention: A Feasibility Study Post-Stroke Cardiovascular Complications and Neurogenic Cardiac Injury: JACC State-of-the-Art Review Two-Year Outcomes and Predictors of Target Lesion Revascularization for Non-Left Main Coronary Bifurcation Lesions Following Two-Stent Strategy With 2nd-Generation Drug-Eluting Stents

Clinical Trial2017 Oct 23;10(20):2113-2123

JOURNAL:JACC Cardiovasc Interv. Article Link

Drug-Coated Balloon Treatment for Femoropopliteal Artery Disease: The IN.PACT Global Study De Novo In-Stent Restenosis Imaging Cohort

Brodmann M, Keirse K, IN.PACT Global Study Investigators Keywords: drug-coated balloon; femoropopliteal artery; in-stent restenosis; paclitaxel; peripheral artery disease

ABSTRACT


OBJECTIVES - This study sought to evaluate the safety and effectiveness of a paclitaxel-coated drug-coatedballoon (DCB) for the treatment of patients with de novo in-stent restenosis (ISR).


BACKGROUND - Treatment of patients with ISR remains a challenge. Current strategies are plagued by high rates of recurrent restenosis and need for reintervention. The best intervention for ISR remains to be elucidated.


METHODS - The IN.PACT Global study is an independently adjudicated multicenter, prospective, single-arm study that enrolled 1,535 subjects with symptomatic atherosclerotic disease of the superficial femoral and/or popliteal arteries, including de novo ISR lesions. Patients enrolled in the pre-specified ISR imaging cohort were evaluated for vessel patency and reintervention within the 12-month follow-up period.


RESULTS - A total of 131 subjects with 149 ISR lesions were included for analysis. The mean age of the cohort was 67.8 years. Mean lesion length was 17.17 ± 10.47 cm, including 34.0% total occlusions and 59.1% calcified lesions. The 12-month Kaplan-Meier estimate of primary patency was 88.7%. The rate of clinically driven target lesion revascularization (CD TLR) at 12 months was 7.3%. The primary safety outcome, a composite of freedom from device- and procedure-related mortality through 30 days and freedom from major target limb amputation and CD TLR within 12 months, was 92.7%. There were no major target limb amputations, no deaths, and a low (0.8%) thrombosis rate.


CONCLUSIONS - Results from the ISR imaging cohort demonstrate high patency and a low rate of CD TLR at 12 months. These data confirm the safety and effectiveness of the IN.PACT Admiral DCB (Medtronic, Dublin, Ireland) in complex femoropopliteal lesions, including this challenging subset.

Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.