In patients with stable coronary heart disease, low-density lipoprotein-cholesterol levels < 70 mg/dL and glycosylated hemoglobin A1c < 7% are associated with lower major cardiovascular events Mechanical circulatory support devices in advanced heart failure: 2020 and beyond Natriuretic Peptide-Guided Heart Failure Therapy After the GUIDE-IT Study Mechanical circulatory support devices for acute right ventricular failure The pyruvate-lactate axis modulates cardiac hypertrophy and heart failure Age-Related Characteristics and Outcomes of Patients With Heart Failure With Preserved Ejection Fraction Association of Left Ventricular Systolic Function With Incident Heart Failure in Late Life Prdm16 Deficiency Leads to Age-Dependent Cardiac Hypertrophy, Adverse Remodeling, Mitochondrial Dysfunction, and Heart Failure Type 2 Diabetes Mellitus and Heart Failure: A Scientific Statement From the American Heart Association and the Heart Failure Society of America SPECT and PET in ischemic heart failure

Clinical Trial2017 Oct 23;10(20):2113-2123

JOURNAL:JACC Cardiovasc Interv. Article Link

Drug-Coated Balloon Treatment for Femoropopliteal Artery Disease: The IN.PACT Global Study De Novo In-Stent Restenosis Imaging Cohort

Brodmann M, Keirse K, IN.PACT Global Study Investigators Keywords: drug-coated balloon; femoropopliteal artery; in-stent restenosis; paclitaxel; peripheral artery disease

ABSTRACT


OBJECTIVES - This study sought to evaluate the safety and effectiveness of a paclitaxel-coated drug-coatedballoon (DCB) for the treatment of patients with de novo in-stent restenosis (ISR).


BACKGROUND - Treatment of patients with ISR remains a challenge. Current strategies are plagued by high rates of recurrent restenosis and need for reintervention. The best intervention for ISR remains to be elucidated.


METHODS - The IN.PACT Global study is an independently adjudicated multicenter, prospective, single-arm study that enrolled 1,535 subjects with symptomatic atherosclerotic disease of the superficial femoral and/or popliteal arteries, including de novo ISR lesions. Patients enrolled in the pre-specified ISR imaging cohort were evaluated for vessel patency and reintervention within the 12-month follow-up period.


RESULTS - A total of 131 subjects with 149 ISR lesions were included for analysis. The mean age of the cohort was 67.8 years. Mean lesion length was 17.17 ± 10.47 cm, including 34.0% total occlusions and 59.1% calcified lesions. The 12-month Kaplan-Meier estimate of primary patency was 88.7%. The rate of clinically driven target lesion revascularization (CD TLR) at 12 months was 7.3%. The primary safety outcome, a composite of freedom from device- and procedure-related mortality through 30 days and freedom from major target limb amputation and CD TLR within 12 months, was 92.7%. There were no major target limb amputations, no deaths, and a low (0.8%) thrombosis rate.


CONCLUSIONS - Results from the ISR imaging cohort demonstrate high patency and a low rate of CD TLR at 12 months. These data confirm the safety and effectiveness of the IN.PACT Admiral DCB (Medtronic, Dublin, Ireland) in complex femoropopliteal lesions, including this challenging subset.

Copyright © 2017 The Authors. Published by Elsevier Inc. All rights reserved.