CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Regional Heterogeneity in the Coronary Vascular Response in Women With Chest Pain and Nonobstructive Coronary Artery Disease Safety and efficacy of a self-expanding versus a balloon-expandable bioprosthesis for transcatheter aortic valve replacement in patients with symptomatic severe aortic stenosis: a randomised non-inferiority trial Systemic microvascular dysfunction in microvascular and vasospastic angina Heart Failure With Improved Ejection Fraction-Is it Possible to Escape One’s Past? Increased glycated albumin and decreased esRAGE levels in serum are related to negative coronary artery remodeling in patients with type 2 diabetes: an Intravascular ultrasound study Aspirin with or without Clopidogrel after Transcatheter Aortic-Valve Implantation Effect of Evolocumab on Complex Coronary Disease Requiring Revascularization Percutaneous Atriotomy for Levoatrial–to–Coronary Sinus Shunting in Symptomatic Heart Failure: First-in-Human Experience Poor Long-Term Survival in Patients With Moderate Aortic Stenosis A trial to evaluate the effect of the sodium-glucose co-transporter 2 inhibitor dapagliflozin on morbidity and mortality in patients with heart failure and reduced left ventricular ejection fraction (DAPA-HF)

Original Research2019 Feb 15;93(S1):772-778.

JOURNAL:Catheter Cardiovasc Interv. Article Link

Optical coherence tomography and intravascular ultrasound assessment of the anatomic size and wall thickness of a muscle bridge segment

Ye Z, Lai Y, Yao Y et al. Keywords: coronary perforation; myocardial bridging

ABSTRACT


OBJECTIVE - To use optical coherence tomography (OCT) and intravascular ultrasound (IVUS) in assessing myocardial bridging (MB) vessel size and wall thickness.

 

BACKGROUND - During stent implantation, MB is associated with complications, especially perforation.

 

METHODS - OCT and IVUS were performed in 56 patients with typical angiographic "milking" from November 2016 to May 2017. The vessel area and thickness in the MB segments and adjacent proximal and distal reference segments were measured and compared with eight normal left anterior descending (LAD) segment (no atherosclerosis in a segment that was at least 20 mm long and that began ~40 mm distal to the LAD ostium).

 

RESULTS - Compared with the reference vessel size distal to the MB segment (6.3 ± 1.8 mm2 ), the IVUS-measured size of the tunneled vessel during diastole was significantly smaller (6.0 ± 1.9 mm2 , p < 0.05) (remodeling index = 0.79 ± 0.18). The minimum intramyocardial arterial wall thickness was 0.16 ± 0.02 mm, significantly thinner than that of the mean reference (0.22 ± 0.03 mm, p < 0.001). The location of the thinnest arterial wall was in the distal and middle MB segments in 45 (80.4%) and 11 (19.6%) patients, respectively, and was not related to the degree of systolic compression or remodeling index. The walls of the middle and distal MB subsegments, but not of the proximal MB subsegment, were thinner than that of the comparison group of normal LADs.

 

CONCLUSION - The coronary vessel involved in an MB is both smaller and thinner than that of the adjacent non-MB segment. This may explain the increased frequency and severity of coronary perforation during stent implantation.

 

© 2019 Wiley Periodicals, Inc.