CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Global Approach to High Bleeding Risk Patients With Polymer-Free Drug-Coated Coronary Stents: The LF II Study EXCELling in Left Main Intervention 2019 Guidelines on Diabetes, Pre-Diabetes and Cardiovascular Diseases developed in collaboration with the EASD ESC Clinical Practice Guidelines Efficacy and safety of low-dose colchicine in patients with coronary disease: a systematic review and meta-analysis of randomized trials Impact of intravascular ultrasound guidance in routine percutaneous coronary intervention for conventional lesions: data from the EXCELLENT trial Active factor XI is associated with the risk of cardiovascular events in stable coronary artery disease patients Comparative effectiveness analysis of percutaneous coronary intervention versus coronary artery bypass grafting in patients with chronic kidney disease and unprotected left main coronary artery disease Evolving concepts in the management of antithrombotic therapy in patients undergoing transcatheter aortic valve implantation Clinical and angiographic outcomes of patients treated with everolimus-eluting stents or first-generation Paclitaxel-eluting stents for unprotected left main disease Membrane type 1 matrix metalloproteinase promotes LDL receptor shedding and accelerates the development of atherosclerosis

Review Article2015 Jul;4(3):285-294.

JOURNAL:Interv Cardiol Clin. Article Link

Assessment and Quantitation of Stent Results by Intracoronary Optical Coherence Tomography

Maehara A, Matsumura M, Mintz GS. Keywords: dissection; malapposition; OCT; stent; minimal stent area

ABSTRACT

Optical coherence tomography evaluation of post stent results includes stent expansion as the absolute minimum stent area ratio by comparing the minimum stent area with the proximal and distal reference lumen areas or mean stent area defined as the total stent volume divided by the analyzed stent length; stent strut malapposition defined when the distance from the center of the blooming artifact and the surface of plaque is greater than the sum of stent thickness and polymer thickness; tissue protrusion through the stent struts; semiquantitative residual thrombus evaluation; and stent edge dissection.