CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Left Main Stenting: What We Have Learnt So Far? Uptake of Drug-Eluting Bioresorbable Vascular Scaffolds in Clinical Practice : An NCDR Registry to Practice Project Myocardial Inflammation Predicts Remodeling and Neuroinflammation After Myocardial Infarction Contemporary Diagnosis and Management of Patients With Myocardial Infarction in the Absence of Obstructive Coronary Artery Disease: A Scientific Statement From the American Heart Association Natural History of Spontaneous Coronary Artery Dissection With Spontaneous Angiographic Healing Patient Characteristics Associated With Antianginal Medication Escalation and De-Escalation Following Chronic Total Occlusion Percutaneous Coronary Intervention: Insights From the OPEN CTO Registry High-sensitivity troponin in the evaluation of patients with suspected acute coronary syndrome: a stepped-wedge, cluster-randomised controlled trial Impact of Oxidative Stress on the Heart and Vasculature: Part 2 of a 3-Part Series Chronic Total Occlusion Percutaneous Coronary Intervention: Evidence and Controversies 2014 AHA/ACC Guideline for the Management of Patients with Non-ST-Elevation Acute Coronary Syndromes: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines

Clinical Trial2017 Oct 20;13(8):962-969

JOURNAL:EuroIntervention. Article Link

Changes in high-sensitivity troponin after drug-coated balloon angioplasty for drug-eluting stent restenosis

Colleran R, Harada Y, Kufner S et al. Keywords: drug-eluting stent; biochemical markers; drug-eluting balloon

ABSTRACT


AIMS - The success of drug-coated balloon therapy might be compromised by intraprocedural particulate embolisation of matrix coating, which may cause downstream microvascular obstruction. We aimed to investigate whether drug-coated balloon therapy was associated with an increase in markers of myocardial necrosis compared with drug-eluting stents or plain balloon angioplasty.


METHODS AND RESULTS - In the ISAR-DESIRE-3 trial, patients with limus-eluting stent restenosis were randomised to treatment with a paclitaxel-coated balloon (PCB), paclitaxel-eluting stent (PES) or balloonangioplasty. We included enrolled patients who had pre- and post-intervention high-sensitivity troponin (hs-TnT) levels available. The delta (peak post-procedure minus baseline) troponin was compared between treatment arms. The association between delta troponin tertiles and three-year mortality was also evaluated. Three hundred and forty-three (343) patients were included, comprising patients treated with PCB (n=115), PES (n=112) and balloon angioplasty (n=116). Groups were well matched in terms of baseline characteristics. There was no difference in delta troponin in patients treated with PCB, PES and balloon angioplasty (36±65, 70±183, and 51±124 ng/L, respectively, p=0.16). Three-year mortality was 7.7%, 8.8% and 14.3% for the 1st, 2nd and 3rd tertiles of delta troponin, respectively, p=0.23.


CONCLUSIONS - In patients with drug-eluting stent restenosis, there was no difference in subclinical myocardial necrosis among patients treated with PCB, PES, and balloon angioplasty.