CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Non-invasive detection of coronary inflammation using computed tomography and prediction of residual cardiovascular risk (the CRISP CT study): a post-hoc analysis of prospective outcome data Comprehensive comparative effectiveness and safety of first-line antihypertensive drug classes: a systematic, multinational, large-scale analysis MINOCA: a heterogenous group of conditions associated with myocardial damage Evolution of antithrombotic therapy in patients undergoing percutaneous coronary intervention: a 40-year journey Comparison of Outcomes of Percutaneous Coronary Intervention on Native Coronary Arteries Versus on Saphenous Venous Aorta Coronary Conduits in Patients With Low Left Ventricular Ejection Fraction and Impella Device Implantation Achieved or Attempted (from the PROTECT II Randomized Trial and the cVAD Registry) 中国肺动脉高压诊断与治疗指南(2021版) Extended antiplatelet therapy with clopidogrel alone versus clopidogrel plus aspirin after completion of 9- to 12-month dual antiplatelet therapy for acute coronary syndrome patients with both high bleeding and ischemic risk. Rationale and design of the OPT-BIRISK double-blinded, placebo-controlled randomized trial Percutaneous Coronary Intervention Using Drug-Eluting Stents Versus Coronary Artery Bypass Grafting for Unprotected Left Main Coronary Artery Stenosis: A Meta-Analysis of Randomized Trials Randomized Evaluation of TriGuard 3 Cerebral Embolic Protection After Transcatheter Aortic Valve Replacement: REFLECT II 2020 ACC Expert Consensus Decision Pathway on Management of Conduction Disturbances in Patients Undergoing Transcatheter Aortic Valve Replacement A Report of the American College of Cardiology Solution Set Oversight Committee

Clinical Trial2018 Jan 1;19(1):59-66.

JOURNAL:Eur Heart J Cardiovasc Imaging. Article Link

Fate of post-procedural malapposition of everolimus-eluting polymeric bioresorbable scaffold and everolimus-eluting cobalt chromiummetallic stent in human coronary arteries: sequential assessment with optical coherence tomography in ABSORB Japan trial

Sotomi Y, Onuma Y, Dijkstra J et al. Keywords: bioresorbable scaffold ; metallic stent ; optical coherence tomography ; randomized controlled trial; strut malapposition

ABSTRACT


AIMS - The natural course of post-procedural incomplete strut apposition (ISA) after the implantation of bioresorbable scaffolds (BVS) remains unknown. The purpose of the present study was to evaluate the fate of post-procedural ISA after everolimus-eluting Absorb BVS in comparison with the second-generation everolimus-eluting cobalt chromium stent (CoCr-EES).

 

METHODS AND RESULTS - Fate of post-procedural ISA was evaluated by serial optical coherence tomography (OCT) in the ABSORB Japan randomized trial [OCT-1 subgroup: 110 paired lesions of post-procedure and 2-year follow-up (BVS 73 lesions vs. CoCr-EES 37 lesions)] with respect to ISA distance. Post-procedure ISA struts were categorized into either resolvedor persistentby matched OCT imaging at 2-year follow-up. Post-procedure %malapposed strut and ISA area were smaller in BVS than in CoCr-EES (%malapposed strut: 4.8 ± 6.9% vs. 9.9 ± 9.8%, P = 0.002; ISA area 0.10 ± 0.18 mm2 vs. 0.23 ± 0.26 mm2, P = 0.003). At 2-year follow-up, the difference diminished, and majority of the ISA struts spontaneously resolved in both arms (%malapposed strut: 0.10 ± 0.46% vs. 0.24 ± 0.65%, P = 0.183). Receiver operating characteristic curve analysis (BVS 661 struts vs. CoCr-EES 807 struts) demonstrated that the best cut-off value of endoluminal ISA distance post-procedure for predicting persistent-ISA at 2-year follow-up was 396 µm for BVS (sensitivity 0.875; specificity 0.851) and 359 µm for CoCr-EES (sensitivity 0.778; specificity 0.881).

 

CONCLUSION - BVS as compared with CoCr-EES allows larger ISA distance at post-procedure, although we should make every effort to minimize post-procedure ISA. The reported cut-off value of OCT-estimated ISA distance at post-stenting for predicting persistent-ISA would be helpful to optimize PCI with BVS and CoCr-EES.