Serial intravascular ultrasound analysis of the main and side branches in bifurcation lesions treated with the T-stenting technique Impact of coronary anatomy and stenting technique on long-term outcome after drug-eluting stent implantation for unprotected left main coronary artery disease Coronary Protection to Prevent Coronary Obstruction During TAVR: A Multicenter International Registry Apolipoprotein A-V is a potential target for treating coronary artery disease: evidence from genetic and metabolomic analyses Infective endocarditis after transcatheter aortic valve implantation: a nationwide study Long-term health outcome and mortality evaluation after invasive coronary treatment using drug eluting stents with or without the IVUS guidance. Randomized control trial. HOME DES IVUS 10-Year Outcomes of Stents Versus Coronary Artery Bypass Grafting for Left Main Coronary Artery Disease Leaflet immobility and thrombosis in transcatheter aortic valve replacement Computed tomography angiography-derived extracellular volume fraction predicts early recovery of left ventricular systolic function after transcatheter aortic valve replacement Assessment and Quantitation of Stent Results by Intracoronary Optical Coherence Tomography

Original Research2018 Dec 20;14(12):e1295-e1303.

JOURNAL:EuroIntervention. Article Link

Device specificity of vascular healing following implantation of bioresorbable vascular scaffolds and bioabsorbable polymer metallic drug-eluting stents in human coronary arteries: the ESTROFA OCT BVS vs. BP-DES study

de la Torre Hernandez JM, Gonzalo N, Otaegui I et al. Keywords: BVS vs. BP-DES; OCT; vascular healing

ABSTRACT

AIMS - We sought to compare vascular healing with bioresorbable everolimus-eluting vascular scaffolds (BVS) and drug-eluting stents with bioabsorbable polymers (BP-DES) at six and 12 months both implanted in the same patients.

 

METHODS AND RESULTS - This was a multicentre and prospective study including patients with at least two comparable lesions to treat. In every patient both BVS and BP-DES (SYNERGY, Orsiro or BioMatrix Flex) were implanted by lesion randomisation. Patients included were evaluated with optical coherence tomography at six or 12 months (2:1). Finally, 68 patients had an examination at six months and 27 patients at 12 months. The rates of uncovered struts at six months were 1.7±3.2% for BVS and 5.3±5.6% for BP-DES (p=0.0001), and at 12 months 0.48±0.72% and 4.8±5%, respectively (p=0.001). Rates of strut malapposition were significantly lower with BVS. There was no significant intra-patient correlation with BP-DES/BVS for endpoints. Evaginations were more frequent and larger with BVS. Discontinuities in BVS were observed in 19.4% at six months and 14.3% at 12 months.

 

CONCLUSIONS - Vascular healing with BVS and BP-DES could be more device-specific than patient-specific. At follow-up, BVS presented fewer uncovered or non-apposed struts than BP-DES but more frequent and larger evaginations. Discontinuities in BVS were relatively frequent at both time points.