CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

A new strategy for discontinuation of dual antiplatelet therapy: the RESET Trial (REal Safety and Efficacy of 3-month dual antiplatelet Therapy following Endeavor zotarolimus-eluting stent implantation) Increased Risk of Valvular Heart Disease in Systemic Sclerosis: An Underrecognized Cardiac Complication Intravascular Ultrasound and Angioscopy Assessment of Coronary Plaque Components in Chronic Totally Occluded Lesions Early Surgery or Conservative Care for Asymptomatic Aortic Stenosis Aspirin with or without Clopidogrel after Transcatheter Aortic-Valve Implantation Effect of Evolocumab on Complex Coronary Disease Requiring Revascularization Transcatheter Aortic Valve Replacement in Low-risk Patients With Bicuspid Aortic Valve Stenosis Serial intravascular ultrasound assessment of very late stent thrombosis after sirolimus-eluting stent placement Coronary plaque redistribution after stent implantation is determined by lipid composition: A NIRS-IVUS analysis Identifying coronary artery disease patients at risk for sudden and/or arrhythmic death: remaining limitations of the electrocardiogram

Original Research2019 May 18;21(7):57.

JOURNAL:Curr Cardiol Rep. Article Link

Diagnosis and Prognosis of Coronary Artery Disease with SPECT and PET

Al Badarin FJ, Malhotra S. Keywords: Coronary artery disease; Diagnosis; Myocardial blood flow; Myocardial perfusion imaging; Prognosis

ABSTRACT

PURPOSE OF REVIEW - Radionuclide myocardial perfusion imaging (MPI) continues to be the most reliable modality for diagnosis of hemodynamically significant coronary artery disease (CAD). The application of radionuclide MPI using single photon emission computed tomography (SEPCT) and positron emission tomography (PET) for CAD is reviewed, with emphasis on diagnosis and risk stratification.


RECENT FINDINGS - Contemporary studies have reported the diagnostic and prognostic value of novel imaging protocols, employing stress-first or stress-only approach. In addition, the superior diagnostic value of PET has been established with a role of assessment of myocardial blood flow to improve risk stratification. The utility of MPI in special populations, such as the elderly, women, and diabetic patients has also been recently evaluated. Furthermore, multicenter studies have reported a similar diagnostic and prognostic value of radionuclide MPI compared with other functional and anatomical techniques for CAD. Radionuclide MPI with SPECT and PET are efficacious for diagnosis and prognosis of CAD. Its universal application in varied patient populations highlights its excellent clinical effectiveness.