CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Multimodality imaging in cardiology: a statement on behalf of the Task Force on Multimodality Imaging of the European Association of Cardiovascular Imaging Effect of Smoking on Outcomes of Primary PCI in Patients With STEMI Advances in Clinical Cardiology 2020: A Summary of Key Clinical Trials Comparison of Stenting Versus Bypass Surgery According to the Completeness of Revascularization in Severe Coronary Artery Disease: Patient-Level Pooled Analysis of the SYNTAX, PRECOMBAT, and BEST Trials Intraaortic Balloon Pump in Cardiogenic Shock Complicating Acute Myocardial Infarction: Long-Term 6-Year Outcome of the Randomized IABP-SHOCK II Trial High-Sensitivity Troponin I Levels and Coronary Artery Disease Severity, Progression, and Long-Term Outcomes Randomized comparison of stent strut coverage following angiography- or optical coherence tomography-guided percutaneous coronary intervention Restenosis, Stent Thrombosis, and Bleeding Complications - Navigating Between Scylla and Charybdis Myocardial Inflammation Predicts Remodeling and Neuroinflammation After Myocardial Infarction 10-Year Coronary Heart Disease Risk Prediction Using Coronary Artery Calcium and Traditional Risk Factors: Derivation in the MESA (Multi-Ethnic Study of Atherosclerosis) With Validation in the HNR (Heinz Nixdorf Recall) Study and the DHS (Dallas Heart Study)

Original Research2019 May 21. doi: 10.1001/jamacardio.2019.1776.

JOURNAL:JAMA Cardiol. Article Link

Outcomes in Patients Treated With Thin-Strut, Very Thin-Strut, or Ultrathin-Strut Drug-Eluting Stents in Small Coronary Vessels: A Prespecified Analysis of the Randomized BIO-RESORT Trial

Buiten RA, Ploumen EH, Zocca P et al. Keywords: stent selection; ultrathin-strut drug-eluting stent; repeated revascularization

ABSTRACT


IMPORTANCE - Stenting small-vessel lesions has an increased adverse cardiovascular event risk. Very thin-strut or ultrathin-strut drug-eluting stents might reduce this risk, but data are scarce.


OBJECTIVE - To assess the outcome of all-comer patients with small coronary vessel lesions treated with 3 dissimilar types of drug-eluting stents.


DESIGN - This is a prespecified substudy of the Comparison of Biodegradable Polymer and Durable Polymer Drug-eluting Stents in an All Comers Population (BIO-RESORT) trial, an investigator-initiated, randomized, patient-blinded comparative clinical drug-eluting stent trial. Patients treated with ultrathin-strut sirolimus-eluting stents, very thin-strut everolimus-eluting stents, or previous-generation thin-strut zotarolimus-eluting stents were enrolled from December 2012 to August 2015. This multicenter trial was conducted in 4 Dutch centers for cardiac intervention. Of all 3514 all-comer BIO-RESORT participants, 1506 patients with treatment in at least 1 small-vessel lesion (reference vessel <2.5 mm) were included. Data were analyzed between September 2018 and February 2019.


MAIN OUTCOMES AND MEASURES - Target lesion failure at 3-year follow-up, a composite of cardiac death, target vessel-related myocardial infarction, or target lesion revascularization, analyzed by Kaplan-Meier methods.


RESULTS - In 1452 of 1506 participants (96.4%) (1057 men [70.2%]; 449 women [29.8%]; mean [SD] age, 64.3 [10.4] years), follow-up was available. Target lesion failure occurred in 36 of 525 patients (7.0%) treated with sirolimus-eluting stents, 46 of 496 (9.5%) with everolimus-eluting stents, and 48 of 485 (10.0%) with zotarolimus-eluting stents (sirolimus-eluting vs zotarolimus-eluting hazard ratio [HR], 0.68; 95% CI, 0.44-1.05; P = .08; everolimus-eluting vs zotarolimus-eluting HR, 0.93; 95% CI, 0.62-1.39; P = .72). There was a difference in target lesion revascularizations between sirolimus-eluting and zotarolimus-eluting stents (2.1% vs 5.3%; HR, 0.40; 95% CI, 0.20-0.81; P = .009) that emerged after the first year of follow-up (1.0% vs 3.7%; P = .006); multivariate analysis showed that sirolimus-eluting stent implantation was independently associated with a lower target lesion revascularization rate at 3-year follow-up (adjusted HR, 0.42; 95% CI, 0.20-0.85; P = .02). In the everolimus-eluting stents, the revascularization rate was 4.0% (vs zotarolimus-eluting, HR, 0.74; 95% CI, 0.41-1.34; P = .31). There was no significant between-stent difference in cardiac death, target vessel myocardial infarction, or stent thrombosis.


CONCLUSIONS AND RELEVANCE - Patients stented in small coronary vessels experienced fewer repeated revascularizations if treated with ultrathin-strut sirolimus-eluting stents vs previous generation thin strut zotarolimus-eluting stents. Further research is required to evaluate the potential effect of particularly thin stent struts.



TRIAL REGISTRATION - ClinicalTrials.gov identifier: NCT01674803.