CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Dynamic Myocardial Ultrasound Localization Angiography Percutaneous coronary intervention using a combination of robotics and telecommunications by an operator in a separate physical location from the patient: an early exploration into the feasibility of telestenting (the REMOTE-PCI study) A Randomized Trial to Assess Regional Left Ventricular Function After Stent Implantation in Chronic Total Occlusion The REVASC Trial Frequency, Regional Variation, and Predictors of Undetermined Cause of Death in Cardiometabolic Clinical Trials: A Pooled Analysis of 9259 Deaths in 9 Trials Long-Term Effect of Ultrathin-Strut Versus Thin-Strut Drug-Eluting Stents in Patients With Small Vessel Coronary Artery Disease Undergoing Percutaneous Coronary Intervention: A Subgroup Analysis of the BIOSCIENCE Randomized Trial Double kissing crush in left main coronary bifurcation lesions: A crushing blow to the rival stenting techniques Biolimus-A9 polymer-free coated stent in high bleeding risk patients with acute coronary syndrome: a Leaders Free ACS sub-study Cardiovascular Biomarkers and Imaging in Older Adults: JACC Council Perspectives Percutaneous Support Devices for Percutaneous Coronary Intervention Society of cardiac angiography and interventions: suggested management of the no-reflow phenomenon in the cardiac catheterization laboratory

Original ResearchVolume 12, Issue 7 Part 2, July 2019

JOURNAL:JACC: Cardiovascular Imaging Article Link

Anatomical and Functional Computed Tomography for Diagnosing Hemodynamically Significant Coronary Artery Disease: A Meta-Analysis

C Celeng, T Leiner, P Maurovich-Horvat et al. Keywords: coronary artery disease; computed tomography; fractional flow reserve; meta-analysis; myocardial perfusion imaging

ABSTRACT


OBJECTIVES - This meta-analysis determined the diagnostic performance of coronary computed tomography (CT) angiography (CTA), CT myocardial perfusion (CTP), fractional flow reserve CT (FFRCT), the transluminal attenuation gradient (TAG), and their combined use with CTA versus FFR as a reference standard for detection of hemodynamically significant coronary artery disease (CAD).

 

BACKGROUND - CTA provides excellent anatomic, albeit limited functional information for the evaluation of CAD. Recently, various functional CT techniques emerged to assess the hemodynamic consequences of CAD.

 

METHODS - This meta-analysis was performed in adherence to the PRISMA (Preferred Reporting Items for Systematic Reviews and Meta-Analyses) guidelines. PubMed, EMBASE, and Web of Science were searched from inception until September 7, 2017. Bayesian random effects analysis was used to compute pooled sensitivity, specificity, and the summary receiver-operating characteristic curve of the index tests and compare them with the FFR as a reference standard. Analyses were performed on vessel and patient levels. Because CTA has excellent sensitivity, specificity was considered most relevant. Individual FFRCT values were collected.

 

RESULTS - Overall, 54 articles and 5,330 patients were included. At vessel level, pooled specificity of CTP (0.86; 95% confidence interval [CI]: 0.76 to 0.93), FFRCT (0.78; 95% CI: 0.72 to 0.83) and TAG (0.77; 95% CI: 0.61 to 0.89) were substantially higher than that of CTA (0.61; 95% CI: 0.54 to 0.68). The addition of FFRCT, CTP, and TAG to CTA resulted in high to excellent specificities (0.80 to 0.92). The summary receiver-operating characteristic curve at vessel level yielded superior diagnostic accuracy for CTP, FFRCT, and combined CTA and CTP, compared with CTA. A subanalysis of on-site versus off-site FFRCT revealed no substantial differences between the sensitivity (0.84 vs. 0.85) and specificity (0.80 vs. 0.73) of the 2 techniques. In a second subanalysis, dynamic CTP showed higher sensitivity (0.85 vs. 0.72), but had a lower specificity (0.81 vs. 0.90) than static CTP.

 

CONCLUSIONS - CTP and FFRCT demonstrated a substantial improvement in the identification of hemodynamically significant CAD compared with CTA; therefore, their integration to clinical workflow before revascularization is recommended.