Six Versus 12 Months of Dual Antiplatelet Therapy After Implantation of Biodegradable Polymer Sirolimus-Eluting Stent: Randomized Substudy of the I-LOVE-IT 2 Trial Twelve or 30 months of dual antiplatelet therapy after drug-eluting stents Temporal Trends in Transcatheter Aortic Valve Replacement in France: FRANCE 2 to FRANCE TAVI Primary Prevention of Sudden Cardiac Death From Focal Lipid Storage to Systemic Inflammation Cardiovascular Considerations in Caring for Pregnant Patients: A Scientific Statement From the American Heart Association Effect of Evolocumab on Complex Coronary Disease Requiring Revascularization Universal Definition and Classification of Heart Failure: A Report of the Heart Failure Society of America, Heart Failure Association of the European Society of Cardiology, Japanese Heart Failure Society and Writing Committee of the Universal Definition of Heart Failure Suture- or Plug-Based Large-Bore Arteriotomy Closure: A Pilot Randomized Controlled Trial Permanent pacemaker use among patients with heart failure and preserved ejection fraction: Findings from the Acute Decompensated Heart Failure National Registry (ADHERE) National Registry

Original ResearchVolume 74, Issue 3, July 2019

JOURNAL:J Am Coll Cardiol. Article Link

Myocardial Infarction Risk Stratification With a Single Measurement of High-Sensitivity Troponin I

Y Sandoval, R Nowak, CR deFilippi et al. Keywords: acute myocardial infarction; high-sensitivity cardiac troponin; risk stratification; troponin

ABSTRACT


BACKGROUND- Limited data exist on rapid risk-stratification strategies using the U.S. Food and Drug Administrationcleared high-sensitivity cardiac troponin I (hs-cTnI) assays.

 

OBJECTIVES- This study sought to examine single measurement hs-cTnI to identify patients at low and high risk for acute myocardial infarction (MI).

 

METHODS- This was a prospective, multicenter, observational study of patients with suspected acute MI enrolled across 29 U.S. sites with hs-cTnI measured using the Atellica IM TnIH and ADVIA Centaur TNIH (Siemens Healthineers) assays. To identify low-risk patients, sensitivities and negative predictive values (NPVs) for acute MI and MI or death at 30 days were examined across baseline hs-cTnI concentrations. To identify high-risk patients, positive predictive values and specificities for acute MI were evaluated.

 

RESULTS- Among 2,212 patients, acute MI occurred in 12%. The limits of detection or quantitation resulted in excellent sensitivities (range 98.6% to 99.6%) and NPVs (range 99.5% to 99.8%) for acute MI or death at 30 days across both assays. An optimized threshold of <5 ng/l identified almost one-half of all patients as low risk, with sensitivities of 98.6% (95% confidence interval: 97.2% to 100%) and NPVs of 99.6% (95% confidence interval: 99.2% to 99.9%) for acute MI or death at 30 days across both assays. For high-risk patients, hs-cTnI 120 ng/l resulted in positive predictive values for acute MI of 70%.

 

CONCLUSIONS- Recognizing the continuous relationship between baseline hs-cTnI and risk for adverse events, using 2 Food and Drug Administrationcleared hs-cTnI assays, an optimized threshold of <5 ng/l safely identified almost one-half of all patients as low risk at presentation, with hs-cTnI 120 ng/l identifying high-risk patients.