CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Assessment and Quantitation of Stent Results by Intracoronary Optical Coherence Tomography A Prospective, Multicenter, Randomized, Open-label Trial to Compare Efficacy and Safety of Clopidogrel vs. Ticagrelor in Stabilized Patients with Acute Myocardial Infarction after Percutan eous Coronary Intervention: rationale and design of the TALOS-AMI trial 5-Year Outcomes Comparing Surgical Versus Transcatheter Aortic Valve Replacement in Patients With Chronic Kidney Disease The contribution of tissue-grouped BMI-associated gene sets to cardiometabolic-disease risk: a Mendelian randomization study EXCELling in Left Main Intervention Pulmonary artery denervation for treatment of a patient with pulmonary hypertension secondary to left heart disease Global Approach to High Bleeding Risk Patients With Polymer-Free Drug-Coated Coronary Stents: The LF II Study Low-density lipoproteins cause atherosclerotic cardiovascular disease: pathophysiological, genetic, and therapeutic insights: a consensus statement from the European Atherosclerosis Society Consensus Panel 2020 ACC Expert Consensus Decision Pathway on Management of Conduction Disturbances in Patients Undergoing Transcatheter Aortic Valve Replacement A Report of the American College of Cardiology Solution Set Oversight Committee Higher neutrophil-to-lymphocyte ratio (NLR) increases the risk of suboptimal platelet inhibition and major cardiovascular ischemic events among ACS patients receiving dual antiplatelet therapy with ticagrelor

Original ResearchVolume 74, Issue 3, July 2019

JOURNAL:J Am Coll Cardiol. Article Link

Myocardial Infarction Risk Stratification With a Single Measurement of High-Sensitivity Troponin I

Y Sandoval, R Nowak, CR deFilippi et al. Keywords: acute myocardial infarction; high-sensitivity cardiac troponin; risk stratification; troponin

ABSTRACT


BACKGROUND- Limited data exist on rapid risk-stratification strategies using the U.S. Food and Drug Administrationcleared high-sensitivity cardiac troponin I (hs-cTnI) assays.

 

OBJECTIVES- This study sought to examine single measurement hs-cTnI to identify patients at low and high risk for acute myocardial infarction (MI).

 

METHODS- This was a prospective, multicenter, observational study of patients with suspected acute MI enrolled across 29 U.S. sites with hs-cTnI measured using the Atellica IM TnIH and ADVIA Centaur TNIH (Siemens Healthineers) assays. To identify low-risk patients, sensitivities and negative predictive values (NPVs) for acute MI and MI or death at 30 days were examined across baseline hs-cTnI concentrations. To identify high-risk patients, positive predictive values and specificities for acute MI were evaluated.

 

RESULTS- Among 2,212 patients, acute MI occurred in 12%. The limits of detection or quantitation resulted in excellent sensitivities (range 98.6% to 99.6%) and NPVs (range 99.5% to 99.8%) for acute MI or death at 30 days across both assays. An optimized threshold of <5 ng/l identified almost one-half of all patients as low risk, with sensitivities of 98.6% (95% confidence interval: 97.2% to 100%) and NPVs of 99.6% (95% confidence interval: 99.2% to 99.9%) for acute MI or death at 30 days across both assays. For high-risk patients, hs-cTnI 120 ng/l resulted in positive predictive values for acute MI of 70%.

 

CONCLUSIONS- Recognizing the continuous relationship between baseline hs-cTnI and risk for adverse events, using 2 Food and Drug Administrationcleared hs-cTnI assays, an optimized threshold of <5 ng/l safely identified almost one-half of all patients as low risk at presentation, with hs-cTnI 120 ng/l identifying high-risk patients.