CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Australian Trends in Procedural Characteristics and Outcomes in Patients Undergoing Percutaneous Coronary Intervention for ST-Elevation Myocardial Infarction Correction of a pathogenic gene mutation in human embryos ACC临床简报:新型冠状病毒对心脏的影响(2019-nCoV) Age-specific gender differences in early mortality following ST-segment elevation myocardial infarction in China Clinical Implications of Periprocedural Myocardial Injury in Patients Undergoing Percutaneous Coronary Intervention for Chronic Total Occlusion: Role of Antegrade and Retrograde Crossing Techniques Blood CSF1 and CXCL12 as Causal Mediators of Coronary Artery Disease Association of All-Cause and Cardiovascular Mortality With High Levels of Physical Activity and Concurrent Coronary Artery Calcification CSC Expert Consensus on Principles of Clinical Management of Patients with Severe Emergent Cardiovascular Diseases during the COVID-19 Epidemic Contemporary Approach to Coronary Bifurcation Lesion Treatment Precision Medicine in TAVR: How to Select the Right Device for the Right Patient

Clinical Trial2019 May 2;380(18):1706-1715.

JOURNAL:N Engl J Med. Article Link

Transcatheter Aortic-Valve Replacement with a Self-Expanding Valve in Low-Risk Patients

Popma JJ, Deeb GM, Evolut Low Risk Trial Investigators. Keywords: TAVR in low-risk patients; severe aortic stenosis; randomized noninferiority trial; noninferiority


BACKGROUND - Transcatheter aortic-valve replacement (TAVR) is an alternative to surgery in patients with severe aortic stenosis who are at increased risk for death from surgery; less is known about TAVR in low-risk patients.

 

METHODS - We performed a randomized noninferiority trial in which TAVR with a self-expanding supraannular bioprosthesis was compared with surgical aortic-valve replacement in patients who had severe aortic stenosis and were at low surgical risk. When 850 patients had reached 12-month follow-up, we analyzed data regarding the primary end point, a composite of death or disabling stroke at 24 months, using Bayesian methods.

 

RESULTS - Of the 1468 patients who underwent randomization, an attempted TAVR or surgical procedure was performed in 1403. The patients' mean age was 74 years. The 24-month estimated incidence of the primary end point was 5.3% in the TAVR group and 6.7% in the surgery group (difference, -1.4 percentage points; 95% Bayesian credible interval for difference, -4.9 to 2.1; posterior probability of noninferiority >0.999). At 30 days, patients who had undergone TAVR, as compared with surgery, had a lower incidence of disabling stroke (0.5% vs. 1.7%), bleeding complications (2.4% vs. 7.5%), acute kidney injury (0.9% vs. 2.8%), and atrial fibrillation (7.7% vs. 35.4%) and a higher incidence of moderate or severe aortic regurgitation (3.5% vs. 0.5%) and pacemaker implantation (17.4% vs. 6.1%). At 12 months, patients in the TAVR group had lower aortic-valve gradients than those in the surgery group (8.6 mm Hg vs. 11.2 mm Hg) and larger effective orifice areas (2.3 cm2 vs. 2.0 cm2).

 

CONCLUSIONS - In patients with severe aortic stenosis who were at low surgical risk, TAVR with a self-expanding supraannular bioprosthesis was noninferior to surgery with respect to the composite end point of death or disabling stroke at 24 months. (Funded by Medtronic; ClinicalTrials.gov number, NCT02701283.).

 

Copyright © 2019 Massachusetts Medical Society.