Blood Pressure Assessment in Adults in Clinical Practice and Clinic-Based Research: JACC Scientific Expert Panel SGLT-2 Inhibitors and Cardiovascular Risk: An Analysis of CVD-REAL Tissue characterisation of atherosclerotic plaque in the left main: an in vivo intravascular ultrasound radiofrequency data analysis 2016 ACC/AHA guideline focused update on duration of dual antiplatelet therapy in patients with coronary artery disease: A report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines Poor R-wave progression as a predictor of sudden cardiac death in general population and subjects with coronary artery disease A pragmatic approach to the use of inotropes for the management of acute and advanced heart failure: An expert panel consensus Evaluation and Management of Right-Sided Heart Failure: A Scientific Statement From the American Heart Association Clopidogrel Pharmacogenetics: State-of-the-Art Review and the TAILOR-PCI Study The Hospital Readmissions Reduction Program Nationwide Perspectives and Recommendations: A JACC: Heart Failure Position Paper A randomized controlled trial to evaluate the safety and efficacy of cardiac contractility modulation in patients with systolic heart failure: rationale, design, and baseline patient characteristics.

Clinical Trial2016 Apr 28;374(17):1609-20.

JOURNAL:N Engl J Med. Article Link

Transcatheter or Surgical Aortic-Valve Replacement in Intermediate-Risk Patients

Leon MB, Smith CR, PARTNER 2 Investigators. Keywords: intermediate-risk patients; TAVI; SAVR:

ABSTACT


BACKGROUND - Previous trials have shown that among high-risk patients with aortic stenosis, survival rates are similar with transcatheter aortic-valve replacement (TAVR) and surgical aortic-valve replacement. We evaluated the two procedures in a randomized trial involving intermediate-risk patients.

METHODS - We randomly assigned 2032 intermediate-risk patients with severe aortic stenosis, at 57 centers, to undergo either TAVR or surgical replacement. The primary end point was death from any cause or disabling stroke at 2 years. The primary hypothesis was that TAVR would not be inferior to surgical replacement. Before randomization, patients were entered into one of two cohorts on the basis of clinical and imaging findings; 76.3% of the patients were included in the transfemoral-access cohort and 23.7% in the transthoracic-access cohort.

RESULTS - The rate of death from any cause or disabling stroke was similar in the TAVR group and the surgery group (P=0.001 for noninferiority). At 2 years, the Kaplan-Meier event rates were 19.3% in the TAVR group and 21.1% in the surgery group (hazard ratio in the TAVR group, 0.89; 95% confidence interval [CI], 0.73 to 1.09; P=0.25). In the transfemoral-access cohort, TAVR resulted in a lower rate of death or disabling stroke than surgery (hazard ratio, 0.79; 95% CI, 0.62 to 1.00; P=0.05), whereas in the transthoracic-access cohort, outcomes were similar in the two groups. TAVR resulted in larger aortic-valve areas than did surgery and also resulted in lower rates of acute kidney injury, severe bleeding, and new-onset atrial fibrillation; surgery resulted in fewer major vascular complications and less paravalvular aortic regurgitation.

CONCLUSIONS - In intermediate-risk patients, TAVR was similar to surgical aortic-valve replacement with respect to the primary end point of death or disabling stroke. (Funded by Edwards Lifesciences; PARTNER 2 ClinicalTrials.gov number, NCT01314313.).