Limitations of Repeat Revascularization as an Outcome Measure Blood Pressure Assessment in Adults in Clinical Practice and Clinic-Based Research: JACC Scientific Expert Panel Sildenafil for improving outcomes in patients with corrected valvular heart disease and persistent pulmonary hypertension: a multicenter, double-blind, randomized clinical trial Incidence and Clinical Outcomes of Stent Fractures on the Basis of 6,555 Patients and 16,482 Drug-Eluting Stents From 4 Centers Left Ventricular Rapid Pacing Via the Valve Delivery Guidewire in Transcatheter Aortic Valve Implantation Intravascular ultrasound findings of early stent thrombosis after primary percutaneous intervention in acute myocardial infarction: a Harmonizing Outcomes with Revascularization and Stents in Acute Myocardial Infarction (HORIZONS-AMI) substudy Healthy Behavior, Risk Factor Control, and Survival in the COURAGE Trial Genetics and Causality of Triglyceride-Rich Lipoproteins in Atherosclerotic Cardiovascular Disease Coronary bifurcation lesions treated with simple or complex stenting: 5-year survival from patient-level pooled analysis of the Nordic Bifurcation Study and the British Bifurcation Coronary Study Optical frequency-domain imaging findings to predict good stent expansion after rotational atherectomy for severely calcified coronary lesions

Original Research2019 Aug 6. doi: 10.7326/M19-1337.

JOURNAL:Ann Intern Med. Article Link

Comparative Accuracy of Focused Cardiac Ultrasonography and Clinical Examination for Left Ventricular Dysfunction and Valvular Heart Disease: A Systematic Review and Meta-analysis

Marbach JA, Almufleh A, Di Santo P et al. Keywords: cardiac ultrasonography; valvular heart disease

ABSTRACT


BACKGROUND - Incorporating focused cardiac ultrasonography (FoCUS) into clinical examination could improve the diagnostic yield of bedside patient evaluation.

 

PURPOSE - To compare the accuracy of FoCUS-assisted clinical assessment versus clinical assessment alone for diagnosing left ventricular dysfunction or valvular disease in adults having cardiovascular evaluation.

 

DATA SOURCES - English-language searches of MEDLINE, Embase, and Web of Science from 1 January 1990 to 23 May 2019 and review of reference citations.

 

STUDY SELECTION - Eligible studies were done in patients having cardiovascular evaluation; compared FoCUS-assisted clinical assessment versus clinical assessment alone for the diagnosis of left ventricular systolic dysfunction, aortic or mitral valve disease, or pericardial effusion; and used transthoracic echocardiography as the reference standard.

 

DATA EXTRACTION - Three study investigators independently abstracted data and assessed study quality.

 

DATA SYNTHESIS - Nine studies were included in the meta-analysis. The sensitivity of clinical assessment for diagnosing left ventricular dysfunction (left ventricular ejection fraction <50%) was 43% (95% CI, 33% to 54%), whereas that of FoCUS-assisted examination was 84% (CI, 74% to 91%). The specificity of clinical assessment was 81% (CI, 65% to 90%), and that of FoCUS-assisted examination was 89% (CI, 85% to 91%). The sensitivities of clinical assessment and FoCUS-assisted examination for diagnosing aortic or mitral valve disease (of at least moderate severity) were 46% (CI, 35% to 58%) and 71% (CI, 63% to 79%), respectively. Both the clinical assessment and the FoCUS-assisted examination had a specificity of 94% (CI, 91% to 96%).

 

LIMITATION - Evidence was scant, persons doing ultrasonography had variable skill levels, and most studies had unclear or high risk of bias.

 

CONCLUSION - Clinical examination assisted by FoCUS has greater sensitivity, but not greater specificity, than clinical assessment alone for identifying left ventricular dysfunction and aortic or mitral valve disease; FoCUS-assisted examination may help rule out cardiovascular pathology in some patients, but it may not be sufficient for definitive confirmation of cardiovascular disease suspected on physical examination.

 

PRIMARY FUNDING SOURCE - None. (PROSPERO: CRD42019124318).