Intravascular ultrasound predictors for edge restenosis after newer generation drug-eluting stent implantation Vaccination Trends in Patients With Heart Failure - Insights From Get With The Guidelines–Heart Failure Intravascular ultrasound-guided implantation of drug-eluting stents to improve outcome: a meta-analysis Impact of Myocardial Scar on Prognostic Implication of Secondary Mitral Regurgitation in Heart Failure Relationship between intravascular ultrasound guidance and clinical outcomes after drug-eluting stents: the assessment of dual antiplatelet therapy with drug-eluting stents (ADAPT-DES) study Comparison of intravascular ultrasound guided versus angiography guided drug eluting stent implantation: a systematic review and meta-analysis Mechanical complications of everolimus-eluting stents associated with adverse events: an intravascular ultrasound study 2018 ACC/AHA/HRS Guideline on the Evaluation and Management of Patients With Bradycardia and Cardiac Conduction Delay: A Report of the American College of Cardiology/American Heart Association Task Force on Clinical Practice Guidelines and the Heart Rhythm Society Heart Failure With Preserved Ejection Fraction in the Young Temporal Trends in Inpatient Use of Intravascular Imaging Among Patients Undergoing Percutaneous Coronary Intervention in the United States

Original Research2019 Aug 6. doi: 10.7326/M19-1337.

JOURNAL:Ann Intern Med. Article Link

Comparative Accuracy of Focused Cardiac Ultrasonography and Clinical Examination for Left Ventricular Dysfunction and Valvular Heart Disease: A Systematic Review and Meta-analysis

Marbach JA, Almufleh A, Di Santo P et al. Keywords: cardiac ultrasonography; valvular heart disease

ABSTRACT


BACKGROUND - Incorporating focused cardiac ultrasonography (FoCUS) into clinical examination could improve the diagnostic yield of bedside patient evaluation.

 

PURPOSE - To compare the accuracy of FoCUS-assisted clinical assessment versus clinical assessment alone for diagnosing left ventricular dysfunction or valvular disease in adults having cardiovascular evaluation.

 

DATA SOURCES - English-language searches of MEDLINE, Embase, and Web of Science from 1 January 1990 to 23 May 2019 and review of reference citations.

 

STUDY SELECTION - Eligible studies were done in patients having cardiovascular evaluation; compared FoCUS-assisted clinical assessment versus clinical assessment alone for the diagnosis of left ventricular systolic dysfunction, aortic or mitral valve disease, or pericardial effusion; and used transthoracic echocardiography as the reference standard.

 

DATA EXTRACTION - Three study investigators independently abstracted data and assessed study quality.

 

DATA SYNTHESIS - Nine studies were included in the meta-analysis. The sensitivity of clinical assessment for diagnosing left ventricular dysfunction (left ventricular ejection fraction <50%) was 43% (95% CI, 33% to 54%), whereas that of FoCUS-assisted examination was 84% (CI, 74% to 91%). The specificity of clinical assessment was 81% (CI, 65% to 90%), and that of FoCUS-assisted examination was 89% (CI, 85% to 91%). The sensitivities of clinical assessment and FoCUS-assisted examination for diagnosing aortic or mitral valve disease (of at least moderate severity) were 46% (CI, 35% to 58%) and 71% (CI, 63% to 79%), respectively. Both the clinical assessment and the FoCUS-assisted examination had a specificity of 94% (CI, 91% to 96%).

 

LIMITATION - Evidence was scant, persons doing ultrasonography had variable skill levels, and most studies had unclear or high risk of bias.

 

CONCLUSION - Clinical examination assisted by FoCUS has greater sensitivity, but not greater specificity, than clinical assessment alone for identifying left ventricular dysfunction and aortic or mitral valve disease; FoCUS-assisted examination may help rule out cardiovascular pathology in some patients, but it may not be sufficient for definitive confirmation of cardiovascular disease suspected on physical examination.

 

PRIMARY FUNDING SOURCE - None. (PROSPERO: CRD42019124318).