CBS 2019
CBSMD教育中心
English

科学研究

科研文章

荐读文献

Characteristics of abnormal post-stent optical coherence tomography findings in hemodialysis patients Physiological Stratification of Patients With Angina Due to Coronary Microvascular Dysfunction Technical aspects of the culotte technique Lipid-rich plaque and myocardial perfusion after successful stenting in patients with non-ST-segment elevation acute coronary syndrome: an optical coherence tomography study Incidence of Adverse Events at 3 Months Versus at 12 Months After Dual Antiplatelet Therapy Cessation in Patients Treated With Thin Stents With Unprotected Left Main or Coronary Bifurcations Elaborately Engineering a Self-Indicating Dual-Drug Nanoassembly for Site-Specific Photothermal-Potentiated Thrombus Penetration and Thrombolysis Double-Kiss-Crush Bifurcation Stenting: Step-by-Step Troubleshooting A Randomized Trial Evaluating Online 3-Dimensional Optical Frequency Domain Imaging-Guided Percutaneous Coronary Intervention in Bifurcation Lesions Japan-United States of America Harmonized Assessment by Randomized Multicentre Study of OrbusNEich's Combo StEnt (Japan-USA HARMONEE) study: primary results of the pivotal registration study of combined endothelial progenitor cell capture and drug-eluting stent in patients with ischaemic coronary disease and non-ST-elevation acute coronary syndrome Metabolic Interactions and Differences between Coronary Heart Disease and Diabetes Mellitus: A Pilot Study on Biomarker Determination and Pathogenesis

Original Research2019 Jul 20;394(10194):230-239.

JOURNAL:Lancet. Article Link

Drug-coated balloon for treatment of de-novo coronary artery lesions in patients with high bleeding risk (DEBUT): a single-blind, randomised, non-inferiority trial

Rissanen TT, Uskela S, DEBUT trial investigators. Keywords: drug-coated balloons vs bare-metal stents; superiorty; non-inferiority;

ABSTRACT


BACKGROUND - The optimal technique of percutaneous coronary intervention in patients at high bleeding risk is not known. The hypothesis of the DEBUT trial was that percutaneous coronary intervention with drug-coated balloons is non-inferior to percutaneous coronary intervention with bare-metal stents for this population.


METHODS - The DEBUT trial is a randomised, single-blind non-inferiority trial done at five sites in Finland. Patients were eligible if they had an ischaemic de-novo lesion in a coronary artery or bypass graft that could be treated with drug-coated balloons, at least one risk factor for bleeding, and a reference vessel diameter of 2·5-4·0 mm. Those with myocardial infarction with ST-elevation, bifurcation lesions needing a two-stent technique, in-stent restenosis, and flow-limiting dissection or substantial recoil (>30%) of the target lesion after predilation were excluded. After successful predilation of the target lesion, patients were randomly assigned (1:1), by use of a computer-generated random sequence, to percutaneous coronary intervention with a balloon coated with paclitaxel and iopromide or a bare-metal stent. The primary outcome was major adverse cardiac events at 9 months. Non-inferiority was shown if the absolute risk difference was no more than 3%. All prespecified analyses were done in the intention-to-treat population. This trial is registered with ClinicalTrials.gov, number NCT01781546.


FINDINGS - Between May 22, 2013, and Jan 16, 2017, 220 patients were recruited for the study and 208 patients were assigned to percutaneous coronary intervention with drug-coated balloon (n=102) or bare metal stent (n=106). At 9 months, major adverse cardiac events had occurred in one patient (1%) in the drug-coated balloon group and in 15 patients (14%) in the bare-metal stent group (absolute risk difference -13·2 percentage points [95% CI -6·2 to -21·1], risk ratio 0·07 [95% CI 0·01 to 0·52]; p<0·00001 for non-inferiority and p=0·00034 for superiority). Two definitive stent thrombosis events occurred in the bare metal stent group but no acute vessel closures in the drug-coated balloon group.


INTERPRETATIONS - Percutaneous coronary intervention with drug-coated balloon was superior to bare-metal stents in patients at bleeding risk. The drug-coated balloon-only coronary intervention is a novel strategy to treat this difficult patient population. Comparison of this approach to the new generation drug-eluting stents is warranted in the future.


FUNDING - B Braun Medical AG, AstraZeneca, and Competitive State Research Funding of the Kuopio University Hospital Catchment Area.

 

Copyright © 2019 Elsevier Ltd. All rights reserved.