Atherosclerosis — An Inflammatory Disease Cardiac resynchronization therapy with a defibrillator (CRTd) in failing heart patients with type 2 diabetes mellitus and treated by glucagon-like peptide 1 receptor agonists (GLP-1 RA) therapy vs. conventional hypoglycemic drugs: arrhythmic burden, hospitalizations for heart failure, and CRTd responders rate ACCF/AHA 2007 clinical expert consensus document on coronary artery calcium scoring by computed tomography in global cardiovascular risk assessment and in evaluation of patients with chest pain: a report of the American College of Cardiology Foundation Clinical Expert Consensus Task Force (ACCF/AHA Writing Committee to Update the 2000 Expert Consensus Document on Electron Beam Computed Tomography) developed in collaboration with the Society of Atherosclerosis Imaging and Prevention and the Society of Cardiovascular Computed Tomography Association of Smoking Status With Long‐Term Mortality and Health Status After Transcatheter Aortic Valve Replacement: Insights From the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry The Use of Sex-Specific Factors in the Assessment of Women’s Cardiovascular Risk Impact of Lesion Preparation Strategies on Outcomes of Left Main PCI: The EXCEL Trial Third-Generation Balloon and Self-Expandable Valves for Aortic Stenosis in Large and Extra-Large Aortic Annuli From the TAVR-LARGE Registry Dual-antiplatelet treatment beyond 1 year after drug-eluting stent implantation (ARCTIC-Interruption): a randomised trial Regional Heterogeneity in the Coronary Vascular Response in Women With Chest Pain and Nonobstructive Coronary Artery Disease Meta-Analysis of Effectiveness and Safety of Transcatheter Aortic Valve Implantation Versus Surgical Aortic Valve Replacement in Low-to-Intermediate Surgical Risk Cohort

Original Research2019 Jul 20;394(10194):230-239.

JOURNAL:Lancet. Article Link

Drug-coated balloon for treatment of de-novo coronary artery lesions in patients with high bleeding risk (DEBUT): a single-blind, randomised, non-inferiority trial

Rissanen TT, Uskela S, DEBUT trial investigators. Keywords: drug-coated balloons vs bare-metal stents; superiorty; non-inferiority;

ABSTRACT


BACKGROUND - The optimal technique of percutaneous coronary intervention in patients at high bleeding risk is not known. The hypothesis of the DEBUT trial was that percutaneous coronary intervention with drug-coated balloons is non-inferior to percutaneous coronary intervention with bare-metal stents for this population.


METHODS - The DEBUT trial is a randomised, single-blind non-inferiority trial done at five sites in Finland. Patients were eligible if they had an ischaemic de-novo lesion in a coronary artery or bypass graft that could be treated with drug-coated balloons, at least one risk factor for bleeding, and a reference vessel diameter of 2·5-4·0 mm. Those with myocardial infarction with ST-elevation, bifurcation lesions needing a two-stent technique, in-stent restenosis, and flow-limiting dissection or substantial recoil (>30%) of the target lesion after predilation were excluded. After successful predilation of the target lesion, patients were randomly assigned (1:1), by use of a computer-generated random sequence, to percutaneous coronary intervention with a balloon coated with paclitaxel and iopromide or a bare-metal stent. The primary outcome was major adverse cardiac events at 9 months. Non-inferiority was shown if the absolute risk difference was no more than 3%. All prespecified analyses were done in the intention-to-treat population. This trial is registered with ClinicalTrials.gov, number NCT01781546.


FINDINGS - Between May 22, 2013, and Jan 16, 2017, 220 patients were recruited for the study and 208 patients were assigned to percutaneous coronary intervention with drug-coated balloon (n=102) or bare metal stent (n=106). At 9 months, major adverse cardiac events had occurred in one patient (1%) in the drug-coated balloon group and in 15 patients (14%) in the bare-metal stent group (absolute risk difference -13·2 percentage points [95% CI -6·2 to -21·1], risk ratio 0·07 [95% CI 0·01 to 0·52]; p<0·00001 for non-inferiority and p=0·00034 for superiority). Two definitive stent thrombosis events occurred in the bare metal stent group but no acute vessel closures in the drug-coated balloon group.


INTERPRETATIONS - Percutaneous coronary intervention with drug-coated balloon was superior to bare-metal stents in patients at bleeding risk. The drug-coated balloon-only coronary intervention is a novel strategy to treat this difficult patient population. Comparison of this approach to the new generation drug-eluting stents is warranted in the future.


FUNDING - B Braun Medical AG, AstraZeneca, and Competitive State Research Funding of the Kuopio University Hospital Catchment Area.

 